The use of customized 3D‐printed mandibular prostheses with pressure‐reducing device: A clinical trial
Authors:
- 8 February 2024
- journal article
- research article
- Published by Wiley in Head & Neck
- Vol. 46 (7) , 1614-1624
Abstract
Background: Segmental bone defects of the mandible result in the complete loss of the affected region. We had incorporated the pressure‐reducing device (PRD) designs into the customized mandible prostheses (CMP) and conducted a clinical trial to evaluate this approach.Methods: Seven patients were enrolled in this study. We examined the association among the history of radiotherapy, the number of CMP regions, the number of chin regions involved, and CMP exposure.Results: We included five men and two women with an average age of 55 years. We excised tumors with an average weight of 147.8 g and the average weight of the CMP was 68.5 g. No significant difference between the two weights was noted (p = 0.3882). Three patients received temporary dentures and the CMP remained stable in all patients.Conclusion: The use of PRD in CMP may address the previous challenges associated with CMP, but further research is necessary.Keywords
Funding Information
- Southern Taiwan Science Park (BX‐03‐04‐04‐ 110)
- Kaohsiung Veterans General Hospital (KSVGH110‐099)
This publication has 47 references indexed in Scilit:
- Finite element analysis of customized implant in mandibular reconstruction after tumor resection with and without using customized surgical osteotomy guideThe International Journal of Medical Robotics and Computer Assisted Surgery, 2017
- Evaluation of laser bacterial anti‐fouling of transparent nanocrystalline yttria‐stabilized‐zirconia cranial implantLasers in Surgery and Medicine, 2016
- Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstructionInternational Journal of Computer Assisted Radiology and Surgery, 2015
- Laryngeal replacement with an artificial larynx after total laryngectomy: The possibility of restoring larynx functionality in the futureHead & Neck, 2014
- Titanium Microbead‐Based Porous Implants: Bead Size Controls Cell Response and Host IntegrationAdvanced Healthcare Materials, 2013
- Different sensitivity of human endothelial cells, smooth muscle cells and fibroblasts to topography in the nano–micro rangeActa Biomaterialia, 2009
- Internal plate fixation of fractures: short history and recent developmentsJournal of Orthopaedic Science, 2006
- Primary oromandibular reconstruction using free flaps and thorp plates in cancer patients: A 5‐year experienceHead & Neck, 2002
- Factors Involved in Long- and Short-term Mandibular Plate ExposureJAMA Otolaryngology–Head & Neck Surgery, 1997
- Titanium‐coated micromachined grooves of different dimensions affect epithelial and connective‐tissue cells differently in vivoJournal of Biomedical Materials Research, 1990