Sensor Fusion for Improved Control of Piezoelectric Tube Scanners
- 23 May 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 16 (6) , 1265-1276
Abstract
In nanopositioning applications, capacitive or inductive sensors are used to measure displacement and provide feedback to eliminate actuator nonlinearity, dynamics, cross-coupling between axes, and thermal drift. Due to their noise density, typically 20 pm/radicHz for 100-mum range transducers, feedback loops are restricted to a few tens of Hertz if nanometer precision is required. In this study, a capacitive displacement sensor is used with a piezoelectric strain voltage measurement to reduce sensor noise at frequencies above 1 Hz. The piezoelectric strain voltage is derived from an open-circuit electrode on a four-quadrant piezoelectric tube actuator and requires no additional hardware. The noise density of the piezoelectric strain voltage is measured to be three orders of magnitude lower than the capacitive sensor. This allows a large increase in closed-loop bandwidth with no penalty on sensor-induced noise. The advantageous properties of the capacitive sensor and piezoelectric strain voltage are discussed and utilized to design a Kalman filter that combines the two signals in a statistically optimal way. A receding horizon control strategy is then introduced as a technique for controlling the tube scanner. A wide-bandwidth controller is implemented that provides reference tracking and damping of the actuator resonance, with root-mean-square displacement noise below 0.4 nm.Keywords
This publication has 24 references indexed in Scilit:
- Iterative Control Approach to Compensate for Both the Hysteresis and the Dynamics Effects of Piezo ActuatorsIEEE Transactions on Control Systems Technology, 2007
- Design of hysteresis-compensating iterative learning control for piezo-positioners: Application to atomic force microscopesMechatronics, 2006
- The application of initial state correction in iterative learning control and the experimental validation on a piezoelectric tube scannerProceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering, 2004
- Fast contact-mode atomic force microscopy on biological specimen by model-based controlUltramicroscopy, 2004
- Design and Control of Optimal Scan Trajectories: Scanning Tunneling Microscope ExampleJournal of Dynamic Systems, Measurement, and Control, 2004
- Model-based signal conditioning for high-speed atomic force and friction force microscopyMicroelectronic Engineering, 2003
- Feedback control of piezoelectric tube scanners2002
- Creep, Hysteresis, and Vibration Compensation for Piezoactuators: Atomic Force Microscopy ApplicationJournal of Dynamic Systems, Measurement, and Control, 1999
- Optimal tracking of piezo-based nanopositionersNanotechnology, 1999
- High-Speed Scanning of Piezo-Probes for Nano-fabricationJournal of Manufacturing Science and Engineering, 1998