Extent of hepatitis E virus elimination is affected by stabilizers present in plasma products and pore size of nanofilters
Authors:
- 9 July 2008
- journal article
- research article
- Published by Wiley in Vox Sanguinis
- Vol. 95 (2) , 94-100
Abstract
Background and Objective To investigate the physico‐chemical properties of hepatitis E virus (HEV) with regard to inactivation/removal, we have studied four isolates with respect to sensitivity to heat during liquid/dry‐heating as well as removal by nanofiltration.Materials and Methods Hepatitis E virus in an albumin solution or phosphate‐buffered saline (PBS) was liquid‐heated at 60°C for a preset time. HEV in a freeze‐dried fibrinogen containing stabilizers was also dry‐heated at 60 or 80°C for a preset time. In addition, to clarify the removal of HEV, the purified virus in PBS was filtered using several types of virus‐removal filter (nanofilters) that have different pore sizes. HEV infectivity or genome equivalents before and after the treatments were assayed by a semiquantitative cell‐based infectivity assay or quantitative polymerase chain reaction assay, respectively.Results Hepatitis E virus isolates in albumin solutions were inactivated slowly at 60°C for 5 h and the resultant log reduction factor (LRF) was from 1·0 to ≥ 2·2, whereas the virus in PBS was inactivated quickly to below the detection limit and the LRF was ≥ 2·4 to ≥ 3·7. The virus in a freeze dried fibrinogen containing trisodium citrate dihydrate and l‐arginine hydrochloride as stabilizers was inactivated slowly and the LRF was 2·0 and 3·0, respectively, of the 72 h at 60°C, but inactivated to below the detection limit within 24 h at 80°C with an LRF of ≥ 4·0. The virus in PBS was also confirmed as to be approximately 35 nm in diameter by nanofiltration. These results are useful for evaluating viral safety against HEV contamination in blood products.Conclusion The sensitivity of HEV to heat was shown to vary greatly depending on the heating conditions. On the other hand, the HEV particles were completely removed using 20‐nm nanofilters. However, each inactivation/removal step should be carefully evaluated with respect to the HEV inactivation/removal capacity, which may be influenced by processing conditions such as the stabilizers used for blood products.Keywords
This publication has 20 references indexed in Scilit:
- Detection and characterization of infectious Hepatitis E virus from commercial pig livers sold in local grocery stores in the USAJournal of General Virology, 2007
- Development and evaluation of an efficient cell-culture system for Hepatitis E virusJournal of General Virology, 2007
- Variability of parvovirus B19 to inactivation by liquid heating in plasma productsVox Sanguinis, 2007
- Effect of manufacturing process parameters on virus inactivation by dry heat treatment at 80 °C in factor VIIIVox Sanguinis, 2006
- Identification of Genotype 1 Hepatitis E Virus in Samples from Swine in CambodiaJournal of Clinical Microbiology, 2006
- Removal of small nonenveloped viruses by antibody‐enhanced nanofiltration during the manufacture of plasma derivativesTransfusion, 2006
- Phylogenetic analysis of global hepatitis E virus sequences: genetic diversity, subtypes and zoonosisReviews in Medical Virology, 2005
- Prevalence of antibodies to hepatitis E virus among Japanese blood donors: Identification of three blood donors infected with a genotype 3 hepatitis E virusJournal of Medical Virology, 2004
- Removal of small non‐enveloped viruses by nanofiltrationVox Sanguinis, 2004
- Novel strains of hepatitis E virus identified from humans and other animal species: is hepatitis E a zoonosis?Journal of Hepatology, 2000