Simultaneous detection of atmospheric HONO and NO2 utilising an IBBCEAS system based on an iterative algorithm
Open Access
- 3 December 2020
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 13 (12) , 6487-6499
Abstract
We present an improved incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS) system based on an iterative retrieval algorithm for the simultaneous detection of atmospheric nitrous acid (HONO) and nitrogen dioxide (NO2). The conventional IBBCEAS retrieval algorithm depends on the absolute change in the light intensity, which requires high light source stability and the stable transmission of the light intensity of all optical components. The new algorithm has an iterative module to obtain the effective absorption optical path length, and the concentrations of HONO and NO2 are then determined by differential optical absorption spectroscopy (DOAS) retrieval; thus, the method is insensitive to the fluctuation in the absolute light intensity. The robustness of the system is verified by simulating the influence of the relative change in the light intensity on the spectral retrieval results. The effect of nitrogen purging in front of the cavity mirrors on shortening the actual cavity length was measured and corrected using NO2 gas samples. Allan deviation analysis was conducted to determine the system stability, and it indicated that the detection limits (2σ) of HONO and NO2 are 0.08 and 0.14 ppbv at an integration time of 60 s respectively. Furthermore, Kalman filtering was used to improve the measurement precision of the system. The measurement precision at an integration time of 3 s can be improved 4.5-fold by applying Kalman filtering, which is equivalent to the measurement precision at an integration time of 60 s without applying Kalman filtering. The atmospheric HONO and NO2 concentrations were observed by the IBBCEAS system based on an iterative algorithm and were compared with values measured by conventional IBBCEAS.Keywords
All Related Versions
Funding Information
- National Natural Science Foundation of China (91544104, 41875154)
This publication has 49 references indexed in Scilit:
- Intercomparison of nitrous acid (HONO) measurement techniques in a megacity (Beijing)Atmospheric Measurement Techniques, 2019
- Development of a Quantum Cascade Laser-Based Sensor for Environmental HONO Monitoring in the Mid-Infrared at 8 μmJournal of Lightwave Technology, 2018
- Development of an incoherent broadband cavity-enhanced absorption spectrometer for in situ measurements of HONO and NO 2Atmospheric Measurement Techniques, 2018
- Portable broadband cavity-enhanced spectrometer utilizing Kalman filtering: application to real-time, in situ monitoring of glyoxal and nitrogen dioxideOptics Express, 2017
- Development of a Home-Made Long Path Absorption Photometer for the Sensitive Detection of Nitrous AcidActa Physico-Chimica Sinica, 2014
- Uptake of Gas Phase Nitrous Acid onto Boundary Layer Soil SurfacesEnvironmental Science & Technology, 2013
- An online monitoring system for atmospheric nitrous acid (HONO) based on stripping coil and ion chromatographyJournal of Environmental Sciences, 2013
- Technical Note: The application of an improved gas and aerosol collector for ambient air pollutants in ChinaAtmospheric Chemistry and Physics, 2012
- Strong daytime production of OH from HNO2 at a rural mountain siteGeophysical Research Letters, 2006
- Impact of nitrous acid photolysis on the total hydroxyl radical budget during the Limitation of Oxidant Production/Pianura Padana Produzione di Ozono study in MilanJournal of Geophysical Research: Atmospheres, 2002