Prognostic value of TAPSE/PASP ratio in right ventricular failure after left ventricular assist device implantation: Experience from a tertiary center
Authors:
Open Access
- 29 July 2022
- journal article
- research article
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 30 (3) , 334-343
Abstract
Background: In this study, we aimed to investigate the prognostic value of the tricuspid annular plane systolic excursion (TAPSE)/ pulmonary arterial systolic pressure (PASP) ratio in right ventricular failure patients undergoing left ventricular assist device implantation. Methods: Between February 2013 and February 2020, a total of 75 heart failure patients (65 males, 10 females; median age: 54 years; range, 21 to 66 years) were retrospectively analyzed. The prognostic value of TAPSE/PASP ratio was assessed using the multivariate Cox regression models and confirmed using the Kaplan-Meier analyses. Results: Forty-one (55.4%) patients had an ischemic heart failure etiology. The indication for assist device implantation was bridge to transplant in 64 (85.3%) patients. The overall survival rates at one, three, and five years following left ventricular assist device implantation were 82.7%, 68%, and 49.3%, respectively. Right ventricular failure was observed in 24 (32%) patients during follow-up. In the multivariate analysis, TAPSE/PASP was found to be independently associated with postoperative right ventricular failure (HR: 1.63; 95% CI: 1.49-2.23). A TAPSE/PASP of 0.34 mm/mmHg was found to be the most accurate predictor value, with lower ratios correlating with right ventricular failure. The Kaplan-Meier analysis showed a better overall survival using a TAPSE/PASP ? of 0.34 mm/mmHg (pConclusion: A lower TAPSE/PASP ratio, particularly lower values than 0.34 mm/mmHg, strongly predicts right ventricular failure after left ventricular assist device implantation in patients with advanced heart failure.Keywords
This publication has 28 references indexed in Scilit:
- Serial Echocardiography Using Tissue Doppler and Speckle Tracking Imaging to Monitor Right Ventricular Failure Before and After Left Ventricular Assist Device SurgeryJACC: Heart Failure, 2013
- Speckle tracking echocardiography as a new technique to evaluate right ventricular function in patients with left ventricular assist device therapyThe Journal of Heart and Lung Transplantation, 2013
- Temporary percutaneous right ventricular support using a centrifugal pump in patients with postoperative acute refractory right ventricular failure after left ventricular assist device implantationEuropean Journal of Cardio-Thoracic Surgery, 2011
- Right-to-left ventricular end-diastolic diameter ratio and prediction of right ventricular failure with continuous-flow left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2011
- Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomesThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceNew England Journal of Medicine, 2009
- Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist deviceThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Tricuspid Annular Motion as a Predictor of Severe Right Ventricular Failure After Left Ventricular Assist Device ImplantationThe Journal of Heart and Lung Transplantation, 2008
- The Right Ventricular Failure Risk ScoreJACC, 2008
- Use of a Continuous-Flow Device in Patients Awaiting Heart TransplantationNew England Journal of Medicine, 2007