Feasibility of replacing the viral isolation technique in mice with RT-qPCR for the diagnosis of rabies
Authors:
- Karina Miranda MarinhoKMKarina Miranda Marinho
- Cássio Alexandre Costa Magalhães JúniorCJCássio Alexandre Costa Magalhães Júnior
- Lúcio André Amorim JúniorLJLúcio André Amorim Júnior
- Lucas Alves ViannaLVLucas Alves Vianna
- Fernando Luiz TobiasFTFernando Luiz Tobias
- Hélio LangoniHLHélio Langoni
- Fabio Ribeiro BragaFBFabio Ribeiro Braga
- Gabriel Augusto Marques RossiGabriel Augusto Marques Rossi
- Luiz Fernando Pereira VieiraLVLuiz Fernando Pereira Vieira
Open Access
- 1 January 2024
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Ciência Rural
- Vol. 54 (8) , e20230229
Abstract
Rabies is a viral encephalitis that affects mammals, including humans. Rapid and effective laboratory diagnosis of the rabies virus is critical for public health. This study evaluated the operational, technical, and financial viability of the RT-qPCR in replacement of inoculation in mice for diagnosing rabies in the laboratory routine. A total of 316 samples of mammalian brains were analyzed, 121 positives and 195 negatives, previously diagnosed by direct immunofluorescence (DIF) and mouse inoculation test (MIT). The samples were submitted to the duplex TaqMan RT-qPCR technique. The accuracy, sensitivity, and specificity of RT-qPCR were analyzed. We analyzed the costs for performing the RT-qPCR technique and compared it with the cost of MIT. The results showed 99.37% accuracy, 99.17% sensitivity, and 99.49% specificity by RT-qPCR when related to DIF and MIT results, which proved to be a robust and repeatable technique. The minimum time for a positive diagnosis was reduced in RT-qPCR (1 day) if compared to MIT (9.64 days), with a 17.7% reduction in the cost of the molecular technique. The present study demonstrated that the molecular biology technique is an efficient tool to diagnose rabies in the laboratory routine, being able to replace MIT.Keywords
This publication has 9 references indexed in Scilit:
- Novel duplex RT‐qPCR for animal rabies surveillanceTransboundary and Emerging Diseases, 2022
- Multi-annual performance evaluation of laboratories in post-mortem diagnosis of animal rabies: Which techniques lead to the most reliable results in practice?PLOS Neglected Tropical Diseases, 2021
- Clarifying Indeterminate Results on the Rabies Direct Fluorescent Antibody Test Using Real-Time Reverse Transcriptase Polymerase Chain ReactionPublic Health Reports®, 2018
- Multi-site evaluation of the LN34 pan-lyssavirus real-time RT-PCR assay for post-mortem rabies diagnosticsPLOS ONE, 2018
- A Pan-Lyssavirus Taqman Real-Time RT-PCR Assay for the Detection of Highly Variable Rabies virus and Other LyssavirusesPLOS Neglected Tropical Diseases, 2017
- Rabies – epidemiology, pathogenesis, public health concerns and advances in diagnosis and control: a comprehensive reviewVeterinary Quarterly, 2017
- Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcomeJournal of Virological Methods, 2016
- Rapid clearance of SAG-2 rabies virus from dogs after oral vaccinationVaccine, 2001
- Rabies Virus in the Decomposed Brain of an Ethiopian Wolf Detected by Nested Reverse Transcription-Polymerase Chain ReactionJournal of Wildlife Diseases, 1997