Magnetic Resonance Spectroscopy as a Non-invasive Method to Quantify Muscle Carnosine in Humans: a Comprehensive Validity Assessment
Preprint
Abstract
Carnosine is a dipeptide abundantly found in human skeletal muscle, cardiac muscle and neuronal cells having numerous properties that confers performance enhancing effects, as well as a wide-range of potential therapeutic applications. A reliable and valid method for tissue carnosine quantification is crucial for advancing the knowledge on biological processes involved with carnosine metabolism. In this regard, proton magnetic resonance spectroscopy (1H-MRS) has been used as a non-invasive alternative to quantify carnosine in human skeletal muscle. However, carnosine quantification by 1H-MRS has some potential limitations that warrant a thorough experimental examination of its validity. The present investigation examined the reliability, accuracy and sensitivity for the determination of muscle carnosine in humans using in vitro and in vivo experiments and comparing it to reference method for carnosine quantification (high-performance liquid chromatography – HPLC). We used in vitro 1H-MRS to verify signal linearity and possible noise sources. Carnosine was determined in the m. gastrocnemius by 1H-MRS and HPLC to compare signal quality and convergent validity. 1H-MRS showed adequate discriminant validity, but limited reliability and poor agreement with a reference method. Low signal amplitude, low signal-to-noise ratio, and voxel repositioning are major sources of error.Keywords
All Related Versions
- Published version: Scientific Reports, 10 (1), 1.
This publication has 43 references indexed in Scilit:
- Associations of age, gender and body mass with 1H MR‐observed brain metabolites and tissue distributionsNMR in Biomedicine, 2011
- State-of-the art data normalization methods improve NMR-based metabolomic analysisMetabolomics, 2011
- Incidence of adverse events associated with percutaneous muscular biopsy among healthy and diseased subjectsScandinavian Journal of Medicine & Science in Sports, 2011
- Fat and water magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- β-Alanine supplementation augments muscle carnosine content and attenuates fatigue during repeated isokinetic contraction bouts in trained sprintersJournal of Applied Physiology, 2007
- Influence of β-alanine supplementation on skeletal muscle carnosine concentrations and high intensity cycling capacityAmino Acids, 2006
- The absorption of orally supplied β-alanine and its effect on muscle carnosine synthesis in human vastus lateralisAmino Acids, 2006
- The Carnosine Content of Vastus Lateralis Is Elevated in Resistance-Trained BodybuildersJournal of Strength & Conditioning Research, 2005
- Quantitative 1H MRS of the human brain in vivo based on the simulation phantom calibration strategyMagnetic Resonance in Medicine, 1998
- Quantitative localized 1H MR spectroscopy for clinical useProgress in Nuclear Magnetic Resonance Spectroscopy, 1997