Effect of peripapillary retinoschisis on retinal nerve fibre layer thickness measurement in glaucomatous eyes
Authors:
- 6 February 2014
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 98 (5) , 669-674
Abstract
Background/aims To investigate the effect of peripapillary retinoschisis on the peripapillary retinal nerve fibre layer (RNFL) thickness measurement by using optical coherence tomography (OCT) in glaucomatous eyes. Methods We included 19 glaucomatous eyes of 19 subjects with peripapillary retinoschisis defined as the splitting of the peripapillary RNFL with schisis cavities (retinoschisis group) and 38 age-matched, refractive error-matched and visual field mean deviation-matched glaucomatous eyes from 38 subjects without peripapillary retinoschisis (control group) that had undergone RNFL thickness measurements by using OCT. RNFL thickness was compared between the two groups. For the retinoschisis group, the RNFL thicknesses prior to peripapillary retinoschisis formation, at the time of peripapillary retinoschisis, and after peripapillary retinoschisis resolution were compared. Results The average RNFL was greater in the eyes in the retinoschisis group (median, 81.6 µm) than in those in the control group (median, 69.7 µm, p=0.009). In the retinoschisis group, the average RNFL thickness at the time of peripapillary retinoschisis was greater than that prior to peripapillary retinoschisis formation (p=0.013) or after peripapillary retinoschisis resolution (p=0.001). The RNFL thickness was not different prior to peripapillary retinoschisis formation and after peripapillary retinoschisis resolution (p>0.05). Conclusions Transient increase in RNFL thickness as determined by OCT was observed in glaucomatous eyes with peripapillary retinoschisis. Caution is warranted when interpreting the RNFL thickness measurement in eyes with peripapillary retinoschisis.Keywords
This publication has 19 references indexed in Scilit:
- Peripapillary Retinal Nerve Fiber Layer Thickening Associated with Vitreopapillary TractionSeminars in Ophthalmology, 2013
- Ability of Cirrus High-Definition Spectral-Domain Optical Coherence Tomography Clock-Hour, Deviation, and Thickness Maps in Detecting Photographic Retinal Nerve Fiber Layer AbnormalitiesOphthalmology, 2013
- Retinal Nerve Fiber Layer Imaging with Spectral-domain Optical Coherence TomographyOphthalmology, 2012
- Effect of Peripapillary Vitreous Opacity on Retinal Nerve Fiber Layer Thickness Measurement Using Optical Coherence TomographyArchives of Ophthalmology (1950), 2012
- Effect of signal strength on reproducibility of circumpapillary retinal nerve fiber layer thickness measurement and its classification by spectral-domain optical coherence tomographyJapanese Journal of Ophthalmology, 2011
- Effect of Partial Posterior Vitreous Detachment on Retinal Nerve Fiber Layer Thickness as Measured by Optical Coherence TomographyArchives of Ophthalmology (1950), 2010
- Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence TomographyOphthalmology, 2009
- A framework for comparing structural and functional measures of glaucomatous damageProgress in Retinal and Eye Research, 2007
- Peripapillary Schisis in Glaucoma Patients With Narrow Angles and Increased Intraocular PressureAmerican Journal of Ophthalmology, 2007
- Measurement of Retinal Nerve Fiber Layer in Primary Acute Angle Closure Glaucoma by Optical Coherence TomographyJournal of Glaucoma, 2007