Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
Open Access
- 26 July 2016
- journal article
- research article
- Published by Springer Nature in Trials
- Vol. 17 (1) , 1-10
Abstract
Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction (p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538 . Registered on 19 January 2015.Keywords
Funding Information
- BD Investigator Initiated Study
- NHMRC Centre for Research Excellence (NCREN) Seed Grant
This publication has 30 references indexed in Scilit:
- Reducing the risk of infection associated with vascular access devices through nanotechnology: a perspectiveInternational Journal of Nanomedicine, 2013
- Short Peripheral Intravenous Catheters and InfectionsJournal of Infusion Nursing, 2012
- Guidelines for the prevention of intravascular catheter-related infectionsAmerican Journal of Infection Control, 2011
- A Randomized Controlled Trial to Compare the Complications of 2 Peripheral Intravenous Catheter-Stabilization SystemsJournal of Infusion Nursing, 2010
- Replacement of peripheral intravenous cathetersJournal of Clinical Nursing, 2008
- Routine care of peripheral intravenous catheters versus clinically indicated replacement: randomised controlled trialBMJ, 2008
- Factors that affect longevity of intravenous cannulas: a prospective studyQJM: An International Journal of Medicine, 2008
- Considerations in determining sample size for pilot studiesResearch in Nursing & Health, 2008
- Prospective surveillance of phlebitis associated with peripheral intravenous cathetersAmerican Journal of Infection Control, 2006
- Normal saline flushing for maintenance of peripheral intravenous sitesJournal of Clinical Nursing, 2005