Age norms for grating acuity and contrast sensitivity in children using eye tracking technology
Authors:
- 7 October 2021
- journal article
- research article
- Published by Springer Nature in International Ophthalmology
- Vol. 42 (3) , 747-756
Abstract
Key messages Visual acuity is the most used method to assess visual function in children. Contrast sensitivity complements the information provided for visual acuity, but it is not commonly used in clinical practice. Digital devices are increasingly used as a method to evaluate visual function, due to multiple advantages. Testing with these devices can improve the evaluation of visual development in children from a few months of age. Visual acuity and contrast sensitivity tests, using eye tracking technology, are able to measure visual function in children across a wide range of ages, objectively, quickly and without need of an experienced examiner. Purpose To report age-normative values for grating visual acuity and contrast sensitivity in healthy children using a digital device with eye tracking technology and to validate the grating acuity test. Methods In the first project of the study, we examined healthy children aged between 6 months and 7 years with normal ophthalmological assessment. Grating visual acuity (VA) and contrast sensitivity (CS) were assessed using a preferential gaze paradigm with a DIVE (Device for an Integral Visual Examination) assisted with eye tracking technology to provide age norms. For the validation project, we compared LEA grating test (LGT) with DIVE VA in a group of children aged between 6 months and 4 years with normal and abnormal visual development. Results Fifty-seven children (2.86 ± 1.55 years) were examined with DIVE VA test and 44 successfully completed DIVE CS test (3.06 ± 1.41 years). Both, VA and CS values increased with age, mainly along the first two years of life. Sixty-nine patients (1.34 ± 0.61 years) were included in the DIVE VA test validation. The mean difference between LGT and DIVE VA was − 1.05 ± 4.54 cpd with 95% limits of agreement (LoA) of − 9.95–7.84 cpd. Agreement between the two tests was higher in children younger than 1 year with a mean difference of − 0.19 ± 4.02 cpd. Conclusions DIVE is an automatic, objective and reliable tool to assess several visual function parameters in children, and it has good agreement with classical VA tests, especially for the first stage of life.Keywords
Funding Information
- Instituto de Salud Carlos III (RD12/0026.)
This publication has 38 references indexed in Scilit:
- Low contrast visual acuity testing is associated with cognitive performance in multiple sclerosis: a cross-sectional pilot studyBMC Neurology, 2013
- Preoperative visual acuity and contrast sensitivity in children with small, partial, or non-central cataractsJournal of American Association for Pediatric Ophthalmology and Strabismus, 2013
- Newborns’ face recognition is based on spatial frequencies below 0.5 cycles per degreeCognition, 2008
- Spatial four-alternative forced-choice method is the preferred psychophysical method for naive observersJournal of Vision, 2006
- Monocular acuity in preschool children: Assessment with the Teller and Keeler acuity cards in comparison to the C-testStrabismus, 1997
- Contrast Sensitivity in 24- and 36-Month-Olds as Assessed with the Contrast Sensitivity Card ProcedureOptometry and Vision Science, 1993
- ASSESSMENT OF VISUAL ACUITY IN INFANTS AND CHILDREN; THE ACUITY CARD PROCEDUREDevelopmental Medicine & Child Neurology, 1986
- The forced-choice preferential looking procedure: A psychophysical technique for use with human infantsInfant Behavior and Development, 1979
- Acuity and contrast sensivity of infant visionNature, 1974
- VISUAL PERCEPTION FROM BIRTH AS SHOWN BY PATTERN SELECTIVITY*Annals of the New York Academy of Sciences, 1965