Diagnostic accuracy of a high-sensitivity troponin I assay and external validation of 0/3 h rule out strategies
- 19 November 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal: Acute Cardiovascular Care
- Vol. 11 (2) , 127-136
Abstract
The timely diagnosis and exclusion of acute coronary syndromes in the Emergency Department (ED) remains a challenge. This study aims to evaluate the diagnostic accuracy of a high-sensitivity cardiac troponin I assay (Siemens TNIH) on serial sampling for ED patients as standalone test and in rule-out algorithms as recommendations remain assay specific. This secondary analysis from a prospective diagnostic accuracy study at 14 centres included ED patients presenting with chest pain of suspected cardiac nature. Serum drawn on arrival and 3 h later was batchtested for TNIH. The target condition was an adjudicated diagnosis of acute myocardial infarction (AMI). We evaluated the diagnostic accuracy of absolute and relative delta criteria and four rule-out strategies. Of 802 included patients, 13.8% had AMI. Absolute delta criteria had superior accuracy to relative criteria (C-statistic 0.94 vs. 0.76, P < 0.001). However, no delta criteria achieved >95.5% sensitivity for AMI when used alone. Ruling out AMI with TNIH below the 99th percentile at 0 and 3 h had 88.3% (95% confidence interval 80.8–93.6%) sensitivity. The adapted European Society of Cardiology (ESC) 0/2 h algorithm had higher sensitivity (98.2%) than both High-STEACS (93.7%, P = 0.03) and the ESC 0/3 h algorithm (79.3%, P < 0.001). These pathways ruled out 63%, 74%, and 88% patients, respectively. With serial sampling over 3 h, the Siemens TNIH assay should be used with a validated algorithm incorporating bespoke cut-offs and absolute delta criteria. In our analysis, the adapted ESC 0/2 h algorithm had greatest sensitivity. ‘Ruling out’ AMI using the 99th percentile of the assay cannot be recommended.Keywords
Funding Information
- Manchester University NHS Foundation Trust
- Siemens Healthineers
- European Union Horizon-2020 scheme
- Royal College of Emergency Medicine; and Abbott Point of Care
This publication has 23 references indexed in Scilit:
- 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevationEuropean Heart Journal, 2015
- Absolute and relative changes (delta) in troponin I for early diagnosis of myocardial infarction: Results of a prospective multicenter trialClinical Biochemistry, 2015
- IFCC educational materials on selected analytical and clinical applications of high sensitivity cardiac troponin assaysClinical Biochemistry, 2015
- Serial changes in high-sensitivity cardiac troponin I in the early diagnosis of acute myocardial infarctionInternational Journal of Cardiology, 2013
- Early Diagnosis of Myocardial Infarction Using Absolute and Relative Changes in Cardiac Troponin ConcentrationsThe American Journal of Medicine, 2013
- What is an acceptable risk of major adverse cardiac event in chest pain patients soon after discharge from the Emergency Department?International Journal of Cardiology, 2013
- How to use high-sensitivity cardiac troponins in acute cardiac careEuropean Heart Journal, 2012
- Utility of Absolute and Relative Changes in Cardiac Troponin Concentrations in the Early Diagnosis of Acute Myocardial InfarctionCirculation, 2011
- Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin AssaysNew England Journal of Medicine, 2009
- The health care burden of acute chest pain: Figure 1Heart, 2005