Abstract
BACKGROUND Thyroid nodule segmentation in ultrasound imaging is clinically important but typically requires large volumes of expert annotations. Foundation models offer a promising approach to reducing labeled data requirements, yet the relationship between annotation budget and segmentation performance across adaptation strategies remains insufficiently characterized. OBJECTIVE Thyroid nodule segmentation in ultrasound imaging is clinically important but typically requires large volumes of expert annotations. Foundation models offer a promising approach to reducing labeled data requirements, yet the relationship between annotation budget and segmentation performance across adaptation strategies remains insufficiently characterized. METHODS We evaluated four SAM3-based adaptation strategies on TN5000 (5,000 biopsy-confirmed thyroid ultrasound images): full fine-tuning (MedSAM3), zero-shot inference (SAM3-Zero), and Low-Rank Adaptation at ranks 8 and 16 (SAM3-LoRA8, SAM3-LoRA16). All models were initialized via Masked Autoencoder pretraining on the unlabeled corpus and evaluated under four annotation regimes (10%, 25%, 50%, and 100% of labeled data) using Dice, IoU, AUC, sensitivity, specificity, and F1-score, with 95% bootstrap confidence intervals and Bonferroni-corrected significance testing. External validation was conducted on the independent DDTI dataset. RESULTS At full annotation budget, MedSAM3 achieved the highest internal performance (Dice = 0.815, AUC = 0.989), significantly outperforming the zero-shot baseline (Dice = 0.097, p < 0.001 across Wilcoxon, DeLong, and McNemar tests). At 25% label availability, SAM3-LoRA8 matched or exceeded MedSAM3 (Dice = 0.736 vs 0.726) while updating only 1.85% of model parameters, identifying 25% as the annotation-efficiency crossover threshold. No statistically significant difference was observed between LoRA ranks 8 and 16 on per-image Dice (Wilcoxon p = 0.704), indicating that increasing rank beyond 8 yields no measurable performance benefit for this task. External validation on the DDTI dataset preserved model ranking (MedSAM3 AUC = 0.911); a dissociation between AUC and Dice under domain shift was observed across all fine-tuned models, with implications for cross-site deployment. CONCLUSIONS Full fine-tuning with domain-adapted initialization provides the best segmentation performance at large annotation budgets. LoRA adaptation with rank 8 offers a more annotation-efficient and parameter-efficient alternative, matching full fine-tuning at 25% label availability and requiring approximately half the training time. These findings provide a concrete decision framework for selecting adaptation strategies in annotation-constrained clinical deployments of thyroid ultrasound segmentation.

This publication has 39 references indexed in Scilit: