Vertebral Augmentation in Spine Surgery
Authors:
- Gordon PrestonGPGordon Preston
- James WhaleyJWJames Whaley
- Jad G. KhalilJKJad G. Khalil
- 23 March 2023
- journal article
- review article
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 31 (10) , 477-489
Abstract
Vertebral augmentation has been a well-studied adjunct percutaneous procedure in spine surgery. Cement augmentation has been used in the treatment of compression fractures through kyphoplasties or vertebroplasties. Historically, data have shown no difference between treating compression fractures conservatively versus with percutaneous cement augmentation procedures. Recent literature has shown improvement in patient outcomes and increase in mobility with percutaneous cement augmentation procedures. Cement augmentation has been used in treating patients with spinal column fractures in higher energy trauma. Cement augmentation has shown to have a reduction in local kyphosis, improved pain, and significant height restoration of the anterior column in patients with burst fractures. Augmentation has been used in spinal deformity surgery, specifically to attempt to reduce the risk of proximal junctional kyphosis and to decrease the risk of screw pullout with cement augmented fenestrated screws in patients with osteoporosis. In pathologic compression fractures, cement augmentation is a safe, viable intervention to improve pain control in these patients. This review will go into the new advances of vertebral augmentation and indications for use in treatment today.Keywords
This publication has 38 references indexed in Scilit:
- Meta-analysis of vertebral augmentation compared with conservative treatment for osteoporotic spinal fracturesJournal of Bone and Mineral Research, 2012
- Pulmonary Cement Embolism Associated with Percutaneous Vertebroplasty or Kyphoplasty: A Systematic ReviewOrthopaedic Surgery, 2012
- Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detectionActa Radiologica, 2012
- Balloon kyphoplasty for the treatment of acute vertebral compression fractures: 2-year results from a randomized trialJournal of Bone and Mineral Research, 2011
- Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-fillingBMC Musculoskeletal Disorders, 2011
- A Randomized Trial of Vertebroplasty for Osteoporotic Spinal FracturesNew England Journal of Medicine, 2009
- A Randomized Trial of Vertebroplasty for Painful Osteoporotic Vertebral FracturesNew England Journal of Medicine, 2009
- Direct Reduction of Thoracolumbar Burst Fractures by Means of Balloon Kyphoplasty With Calcium Phosphate and Stabilization With Pedicle-Screw Instrumentation and FusionSpine, 2008
- Treatment of thoracolumbar burst fractures without neurologic deficit by indirect reduction and posterior instrumentation: bisegmental stabilization with monosegmental fusionEuropean Spine Journal, 1999
- 1992 Volvo Award in Experimental Studies Vertebral Burst FracturesSpine, 1992