Effect of Platelet-Rich-Plasma (PRP) and Implant Surface Topography on Implant Stability and Bone
Author:
Open Access
- 1 January 2014
- journal article
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
- Vol. 8 (6) , ZC26-30
Abstract
To evaluate the effect of Platelet-Rich-Plasma (PRP) and different implant surface topography on implant stability and bone levels around immediately loaded dental implants. Dental implants were placed in subjects divided into two groups and four subgroups on basis of implant treatment with PRP and implant surface topography used. A total of 30 implants were placed, 15 in each group. For PRP group, implants were placed after surface treatment with PRP. Temporization was done within two weeks and final prosthesis was given after three months. Implant stability was measured with Periotest at baseline, one month and three months. Bone height was measured on mesial & distal side on standardized IOPA x-rays. A statistically significant difference was noticed in implant stability with PRP at baseline. The effect of PRP on bone height changes was not statistically significant. A synergistic effect of PRP and square thread-form was observed on improved implant stability and bone levels; however, no such effect is seen with PRP and reverse buttress thread-form. Within the limitation of this study, enhancement on implant stability and bone healing was observed with PRP treated implant surfaces, and with use of implant with square thread-form.Keywords
This publication has 22 references indexed in Scilit:
- Evaluation of immediately loaded dental implants bioactivated with platelet-rich plasma placed in the mandibular posterior region: A clinico-radiographic studyJournal of Indian Society of Periodontology, 2012
- Secondary stability assessment of titanium implants with an alkali-etched surface: a resonance frequency analysis study in beagle dogs.2008
- Multivariate study of factors influencing primary dental implant stabilityClinical Oral Implants Research, 2007
- Early implant failure. Prognostic capacity of Periotest®: retrospective study of a large sampleClinical Oral Implants Research, 2006
- Enhancement of Osseointegration by Generating a Dynamic Implant SurfaceJournal of Oral Implantology, 2006
- Reliability of Linear Distance Measurement for Dental Implant Length with Standardized Periapical RadiographsThe Bulletin of Tokyo Dental College, 2006
- Biologic determinants of bone formation for osseointegration: Clues for future clinical improvementsThe Journal of Prosthetic Dentistry, 1998
- Biomechanical factors affecting the bone-dental implant interfaceClinical Materials, 1992
- The long-term efficacy of currently used dental implants: a review and proposed criteria of success.1986
- Intra-Osseous Anchorage of Dental Prostheses:I. Experimental StudiesScandinavian Journal of Plastic and Reconstructive Surgery, 1969