Fecal Fat Measurement in the Presence of Long- and Medium-Chain Triglycerides and Fatty Acids Comparison of Three Methods
Authors:
- I. VantiniIVI. Vantini
- C. SembeniniCSC. Sembenini
- B. GregoriBGB. Gregori
- V. CarnielliVCV. Carnielli
- L. BeniniLBL. Benini
- 1 January 1996
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 31 (9) , 863-867
Abstract
It has been suggested that some of the limitations of the Van de Kamer method for fecal fat measurement could be overcome with the Jeejeebhoy method or the near-infrared reflectance assay. To test this hypothesis, a fecal fat test was carried out with the three methods, adding butter or MCT oil to the diet of four steatorrhoic patients. An in vitro recovery study of long- and medium-chain triglycerides was also performed. The Jeejeebhoy method measured long- and medium-chain fats more accurately than the Van de Kamer method. It found consistently higher steatorrhea values. Mean results of the near-infrared reflectance analysis resembled those of the Van de Kamer method, but with wide discordance of individual data. The Jeejeebhoy method is more accurate than the Van de Kamer method for fecal fat measurement. The difference may be clinically relevant when most fecal fatty acids derive from medium-chain triglycerides. Near-infrared reflectance may be a viable proposition only when a greater degree of approximation is acceptable.Keywords
This publication has 19 references indexed in Scilit:
- Medium-Chain Triglyceride Absorption in Patients with Pancreatic InsufficiencyScandinavian Journal of Gastroenterology, 1996
- Pancreatic Extracts Are Necessary for the Absorption of Elemental and Polymeric Enteral Diets in Severe Pancreatic InsufficiencyScandinavian Journal of Gastroenterology, 1993
- Near infrared reflectance measurement of nitrogen faecal losses.Gut, 1992
- Near infrared spectrometry for faecal fat measurement: comparison with conventional gravimetric and titrimetric methods.Gut, 1989
- Measuring faecal fatBMJ, 1988
- Measuring faecal fatBMJ, 1988
- Effect of repack on calibrations produced for near-infrared reflectance analysisAnalytical Chemistry, 1986
- Unique-sample selection via near-infrared spectral subtractionAnalytical Chemistry, 1985
- Malabsorption of medium-chain triglycerides in infants with cystic fibrosis: Correction with pancreatic enzyme supplementsThe Journal of Pediatrics, 1980
- The effect of medium chain triglyceride upon fat absorption and plasma lipid and depot fat of children with cystic fibrosis of the pancreas.Journal of Clinical Investigation, 1965