Structural and Functional Lung Assessment in Neonates With Moderate to Severe Bronchopulmonary Dysplasia Using 3D Ultra‐Short Echo Time MRI
- 12 December 2025
- journal article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 970-983
Abstract
Background: 2D multi‐slice MRI techniques for evaluating regional ventilation in neonatal lung diseases, including bronchopulmonary dysplasia (BPD), have limited through‐plane resolution, potentially missing heterogeneous lung abnormalities. 3D ultra‐short echo time (UTE) MRI phase‐resolved functional lung (PREFUL) improves spatial resolution but has not been used to evaluate infants with BPD. Purpose: To demonstrate the feasibility of 3D UTE MRI for structural and functional assessment in infants with BPD. Study Type: Retrospective. Population: A total of 28 infants with BPD (female: male = 8:20; 14 required invasive ventilation at MRI, 14 required non‐invasive ventilation). Field Strength/Sequence: Free‐breathing, respiratory bellows‐gated (acquired 1.19–1.25 mm 3 isotropic) 3D gradient echo UTE MRI on a 1.5 T scanner. Assessment: Images were retrospectively reconstructed into 24 respiratory phases with motion‐resolved reconstruction using compressed sensing. Regional ventilation (RVent), flow‐volume loop cross correlation metric (FVL‐CM), and corresponding ventilation defect maps (VDP RVent , VDP FVL‐CM , and the combination, VDP combined ) were derived using the 3D PREFUL method. Structural lung abnormalities were assessed by two readers using a modified Ochiai scoring system, and parenchyma was defined as normal intensity, hypointense, or hyperintense. Statistical Tests: The Mann–Whitney U Test, Spearman's correlation, and the Kruskal–Wallis test with Dunn's multiple‐comparisons tests were used. Statistical significance was defined as p < 0.05. Results: In the mechanically ventilated infants VDP FVL‐CM (median [IQR] = 45.8 [28.5–55.9]%) and VDP combined (57.2% [35.2–69.3]%) were significantly higher as compared to non‐ventilated patients (VDP FVL‐CM = 22.8% [17.2–34.7]% and VDP combined = 30.7 [25.1–43.9]%). All PREFUL MRI VDP measures significantly correlated with total lung score (all ρ ≥ 0.45). RVent was significantly lower in hyperintense regions (0.06 [0.04–0.08] mL/mL) compared to normal intensity regions (0.09 [0.07–0.13] mL/mL), whereas FVL‐CM was significantly decreased in hypointense regions (79 [66–87]%) compared to normal (92 [90–95]%) and hyperintense regions (91 [81–96]%). Data Conclusion: UTE MRI is feasible for assessing regional functional lung abnormalities in infants with BPD that directly correlate with reader‐based assessments of parenchymal disease severity. Evidence Level: 4. Technical Efficacy: Stage 1.Keywords
Funding Information
- National Institutes of Health (NIH HL146689)
This publication has 42 references indexed in Scilit:
- Pulmonary MRI in Newborns and ChildrenJournal of Magnetic Resonance Imaging, 2024
- Clinical Feasibility of Structural and Functional MRI in Free‐Breathing Neonates and InfantsJournal of Magnetic Resonance Imaging, 2022
- Pediatric 129Xe Gas‐Transfer MRI—Feasibility and ApplicabilityJournal of Magnetic Resonance Imaging, 2022
- Flow Volume Loop and Regional Ventilation Assessment Using Phase‐Resolved Functional Lung (PREFUL) MRI: Comparison With 129Xenon Ventilation MRI and Lung Function TestingJournal of Magnetic Resonance Imaging, 2020
- Proton MRI of the Lung: How to Tame Scarce Protons and Fast Signal DecayJournal of Magnetic Resonance Imaging, 2020
- MRI‐derived regional flow‐volume loop parameters detect early‐stage chronic lung allograft dysfunctionJournal of Magnetic Resonance Imaging, 2019
- Quantitative Assessment of Regional Dynamic Airway Collapse in Neonates via Retrospectively Respiratory‐Gated 1H Ultrashort Echo Time MRIJournal of Magnetic Resonance Imaging, 2018
- Quantification of neonatal lung parenchymal density via ultrashort echo time MRI with comparison to CTJournal of Magnetic Resonance Imaging, 2017
- Pulmonary MRI of neonates in the intensive care unit using 3D ultrashort echo time and a small footprint MRI systemJournal of Magnetic Resonance Imaging, 2016
- The Use of Computed Tomography in Pediatrics and the Associated Radiation Exposure and Estimated Cancer RiskJAMA Pediatrics, 2013