Simulating dose reduction for myocardial perfusion SPECT using a Poisson resampling method
Open Access
- 13 August 2021
- journal article
- research article
- Published by Springer Nature in Nuclear Medicine and Molecular Imaging
- Vol. 55 (5) , 245-252
Abstract
Purpose The purpose of this study was to determine the lowest Tl-201 dose that does not reduce the image quality of myocardial perfusion SPECT (MPS) by Poisson resampling simulation. Methods One hundred and twelve consecutive MPS data from patients with suspected or known coronary artery disease were collected retrospectively. Stress and rest MPS data were resampled using the Poisson method with 33%, 50%, 67%, and 100% count settings. Two nuclear medicine physicians assessed the image quality of reconstructed data visually by giving grades from − 2 to + 2. The summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) were obtained on the workstation. Image quality grades and semi-quantitative scores were then compared among these resampled images. Results The proportions of “adequate” image quality were 0.48, 0.75, 0.92, and 0.96 for the groups of images with 33%, 50%, 67%, and 100% data, respectively. The quality of the resampled images was significantly degraded at 50% and 33% count settings, while the image quality was not different between 67 and 100% count settings. We also found that high body mass index further decreased image quality at 33% count setting. Among the semi-quantitative parameters, SSS and SRS showed a tendency to increase with a decline in count. Conclusion Based on the simulation results, Tl-201 dose for MPS can be reduced to 74 MBq without significant loss of image quality. However, the SSS and SRS can be changed significantly, and it needs to be further verified under the different conditions.Keywords
This publication has 23 references indexed in Scilit:
- Clinical validation of time reduction strategy in continuous step-and-shoot mode during SPECT acquisitionEJNMMI Physics, 2021
- The prognostic value of ultra low-dose thallium myocardial perfusion protocol using CZT SPECTThe International Journal of Cardiovascular Imaging, 2019
- Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imagingJournal of Nuclear Cardiology, 2016
- EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revisionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- ICRP Publication 128: Radiation Dose to Patients from Radiopharmaceuticals: a Compendium of Current Information Related to Frequently Used SubstancesAnnals of the ICRP, 2015
- A Poisson resampling method for simulating reduced counts in nuclear medicine imagesPhysics in Medicine & Biology, 2015
- 4D reconstruction for low-dose cardiac gated SPECTMedical Physics, 2013
- Feasibility of myocardial perfusion imaging with half the radiation dose using ordered-subset expectation maximization with resolution recovery softwareJournal of Nuclear Cardiology, 2012
- Myocardial Perfusion Imaging with 201TlJournal of Nuclear Medicine Technology, 2010
- Procedure Guideline for Myocardial Perfusion Imaging 3.3Journal of Nuclear Medicine Technology, 2008