Behaviour of steel–concrete–steel sandwich composite beams with lacing subjected to reversed cyclic loads
Authors:
- 6 September 2017
- journal article
- research article
- Published by SAGE Publications in Journal of Sandwich Structures & Materials
- Vol. 21 (6) , 1799-1819
Abstract
Steel–concrete–steel (SCS) sandwich composite system consists of steel plates covering both sides of the concrete core and connected by mechanical means such as shear connectors. In conventional steel–concrete–steel system, shear connectors are welded to the steel cover plates. Laced steel–concrete composite (LSCC) system is a new form of steel–concrete–steel, proposed earlier by the authors. In LSCC system, steel cover plates are connected in a novel way using lacings and cross rods and hence is devoid of welding. Proposed sandwich composite system is being evaluated systematically for its structural behaviour under various modes of loading for use in special structures under severe loading such as blast loading. Damage under cyclic loading and energy absorption are extremely important, which are highlighted in this paper. An experimental investigation on the cyclic response behaviour of two LSCC beams is carried out. Angle of lacing is the parameter that is varied between the two beams. Both the beams are found to exhibit similar behaviour on most of the aspects. The envelope of hysteretic response indicates mild softening behaviour after reaching peak value. Maximum load resisted under both sagging and hogging moment conditions is found to be nearly equal, thus making the LSCC system suitable for situations where reversal of loads are encountered. Dissipated energy is observed to be nearly the same for the load applied in the upward as well as in the downward direction. Analytical prediction on energy absorption capacity is carried out by adopting a hysteretic model with strength deterioration. Cyclic ductility factor is evaluated to be about 20 for LSCC beams, while support rotation is calculated to be about 8° and 10° for beams with 45° and 60° angles of lacing, respectively. Spalling of concrete is prevented in LSCC beams by the steel cover plates.Keywords
This publication has 13 references indexed in Scilit:
- Mechanical properties analysis of steel– concrete–steel composite beamJournal of Sandwich Structures & Materials, 2015
- Ultimate strength behavior of curved steel–concrete–steel sandwich composite beamsJournal of Constructional Steel Research, 2015
- Flexural response of steel-fiber-reinforced concrete beams: Effects of strength, fiber content, and strain-rateCement and Concrete Composites, 2015
- Flexural behavior of lightly and heavily reinforced steel fiber concrete beamsConstruction and Building Materials, 2015
- Behavior of steel fiber reinforced concrete-filled steel tube columns under axial compressionConstruction and Building Materials, 2015
- Structural behaviour of double skin composite system using ultra-lightweight cement compositeConstruction and Building Materials, 2015
- Failure mechanism and shear strength of steel–concrete–steel sandwich deep beamsJournal of Constructional Steel Research, 2015
- Shear tests of reinforced concrete beams with continuous rectangular spiral reinforcementConstruction and Building Materials, 2013
- Behavior of Steel–Concrete–Steel sandwich structures with lightweight cement composite and novel shear connectorsComposite Structures, 2012
- Lightweight steel–concrete–steel sandwich system with J-hook connectorsEngineering Structures, 2009