Reduced accuracy of MRI deep grey matter segmentation in multiple sclerosis: an evaluation of four automated methods against manual reference segmentations in a multi-center cohort
Authors:
- Alexandra de SitterASAlexandra de Sitter
- the MAGNIMS Study GroupTGthe MAGNIMS Study Group
- Viktor WottschelVWViktor Wottschel
Open Access
- 3 July 2020
- journal article
- research article
- Published by Springer Nature in Journal of Neurology
- Vol. 267 (12) , 3541-3554
Abstract
Background Deep grey matter (DGM) atrophy in multiple sclerosis (MS) and its relation to cognitive and clinical decline requires accurate measurements. MS pathology may deteriorate the performance of automated segmentation methods. Accuracy of DGM segmentation methods is compared between MS and controls, and the relation of performance with lesions and atrophy is studied. Methods On images of 21 MS subjects and 11 controls, three raters manually outlined caudate nucleus, putamen and thalamus; outlines were combined by majority voting. FSL-FIRST, FreeSurfer, Geodesic Information Flow and volBrain were evaluated. Performance was evaluated volumetrically (intra-class correlation coefficient (ICC)) and spatially (Dice similarity coefficient (DSC)). Spearman's correlations of DSC with global and local lesion volume, structure of interest volume (ROIV), and normalized brain volume (NBV) were assessed. Results ICC with manual volumes was mostly good and spatial agreement was high. MS exhibited significantly lower DSC than controls for thalamus and putamen. For some combinations of structure and method, DSC correlated negatively with lesion volume or positively with NBV or ROIV. Lesion-filling did not substantially change segmentations. Conclusions Automated methods have impaired performance in patients. Performance generally deteriorated with higher lesion volume and lower NBV and ROIV, suggesting that these may contribute to the impaired performance.Keywords
Funding Information
- Amsterdam UMC
This publication has 36 references indexed in Scilit:
- Progression of regional grey matter atrophy in multiple sclerosisBrain, 2018
- The value of including thalamic atrophy as a clinical trial endpoint in multiple sclerosisNeurology, 2018
- Urgent challenges in quantification and interpretation of brain grey matter atrophy in individual MS patients using MRINeuroImage: Clinical, 2018
- Cognitive reserve moderates the impact of subcortical gray matter atrophy on neuropsychological status in multiple sclerosisMultiple Sclerosis Journal, 2015
- Accurate GM atrophy quantification in MS using lesion-filling with co-registered 2D lesion masksNeuroImage: Clinical, 2014
- Evaluating and reducing the impact of white matter lesions on brain volume measurementsHuman Brain Mapping, 2011
- A Bayesian model of shape and appearance for subcortical brain segmentationNeuroImage, 2011
- Reducing the impact of white matter lesions on automated measures of brain gray and white matter volumesJournal of Magnetic Resonance Imaging, 2010
- Evaluation of automated techniques for the quantification of grey matter atrophy in patients with multiple sclerosisNeuroImage, 2010
- Segmentation of brain magnetic resonance images for measurement of gray matter atrophy in multiple sclerosis patientsNeuroImage, 2008