Assessment of distal access catheter performance during neuroendovascular procedures: measuring force in three-dimensional patient specific phantoms
- 4 December 2018
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 11 (6) , 619-622
Abstract
Background The amount of force applied on a device is an important measure to evaluate the endovascular and surgical device manipulations. The measure has not been evaluated for neuroenodvascular procedures. Purpose We aimed to study the use of force measure as a novel approach to test distal access catheter (DAC) performance during catheterization of cervical and intracranial vessels using patient specific 3-dimentional (3D) phantoms. Methods Using patient specific 3D phantoms of the cervical and intracranial circulation, we recorded measure of force required to deliver three types of DACs beyond the ophthalmic segment of the internal carotid artery. Six different combinations of DAC–microcatheter–guidewire were tested. We intentionally included what we considered suboptimal combinations of DACs, microcatheters, and guidewires during our experiments to test the feasibility of measuring force under different conditions. A six axis force sensor was secured to the DAC with an adjustable torque used to track axially directed push and pull forces required to navigate the DAC to the target site. Results In a total of 55 experiments, we found a significant difference in the amount of force used between different DACs (mean force for DAC A, 1.887±0.531N; for DAC B, 2.153±1.280 N; and for DAC C, 1.194±0.521 N, P=0.007). There was also a significant difference in force measures among the six different catheter systems (P=0.035). Conclusions Significant difference in the amount of force used between different DACs and catheter systems were recorded. Use of force measure in neuroendovascular procedures on 3D printed phantoms is feasible.Keywords
This publication has 15 references indexed in Scilit:
- Objective Assessment of Endovascular Navigation Skills with Force SensingAnnals of Biomedical Engineering, 2017
- Reducing contact forces in the arch and supra-aortic vessels using the Magellan robotJournal of Vascular Surgery, 2016
- Initial experience with SOFIA as an intermediate catheter in mechanical thrombectomy for acute ischemic strokeJournal of NeuroInterventional Surgery, 2016
- Catheter manipulation analysis for objective performance and technical skills assessment in transcatheter aortic valve implantationInternational Journal of Computer Assisted Radiology and Surgery, 2016
- Treatment planning for image-guided neuro-vascular interventions using patient-specific 3D printed phantomsProceedings of SPIE, 2015
- Comparison of Modern Stroke Thrombectomy Approaches Using an In Vitro Cerebrovascular Occlusion ModelAmerican Journal of Neuroradiology, 2014
- Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparisonJournal of NeuroInterventional Surgery, 2014
- Assessment of Laparoscopic Skills Based on Force and Motion ParametersIEEE Transactions on Biomedical Engineering, 2014
- Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization deviceJournal of NeuroInterventional Surgery, 2013
- Learning-Based Modeling of Endovascular Navigation for Collaborative Robotic CatheterizationLecture Notes in Computer Science, 2013