Abstract
The binding energies of Si29, S33, and Cl36 have been measured with a relative uncertainty of <0.59×10−6 using a flat-crystal spectrometer. The unique features of these measurements are (1) nearly perfect crystals whose lattice spacing is known in meters, (2) a highly precise angle scale that is derived from first principles, and (3) a γ-ray measurement facility that is coupled to a high-flux reactor with near-core source capability. The binding energy is obtained by measuring all γ-rays in a cascade scheme connecting the capture and ground states. The measurements require the extension of precision flat-crystal diffraction techniques to the 5- to 6-MeV energy region, a significant precision measurement challenge. The binding energies determined from these γ-ray measurements are consistent with recent highly accurate atomic-mass measurements within a relative uncertainty of 4.3×10−7. The γ-ray measurement uncertainties are the dominant contributors to the uncertainty of this consistency test. The measured γ-ray energies are in agreement with earlier precision γ-ray measurements.