Transcutaneous continuous carbon dioxide tension monitoring reduced incidence, degree and duration of hypercapnia during combined regional anaesthesia and monitored anaesthesia care in shoulder surgery patients
Authors:
- 14 October 2014
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 29 (4) , 499-507
Abstract
We studied the impact of transcutaneous continuous carbon dioxide tension (PtcCO2) monitoring on ventilation and oxygenation during monitored anaesthesia care (MAC) in patients scheduled for shoulder surgery with continuous interscalene block. 50 patients were randomised either to the intervention (I-group) or the control (C-group) group. In both groups MAC was performed using target controlled infusion of propofol and remifentanil. MAC regimen was adapted to PtcCO2 values in the I-group, whereas the C-group was blinded for these values. Primary outcome was the incidence, degree and duration of hypoventilation stages. In the I-group and the C-group the mean ± SD [range] of PtcCO2 and PaCO2 was 5.79 ± 0.84 [4.37] and 5.44 ± 0.59 [2.78] kPa, as well as 6.41 ± 1.17 [6.29] and 6.01 ± 0.96 [7.15] kPa. Periods of PtcCO2/PaCO2 > 6.5 kPa were 21.0 ± 35.7/1.2 ± 4.2 min in the I-group and 45.6 ± 40.0/18.6 ± 26.8 min in the C-group. Severe hypercapnia (PtcCO2 and/or PaCO2 > 7.5 kPa) was dected in 3/0 patients of the I-group and in 10/3 patients of the C-group. PtcCO2 and PaCO2 showed a strong correlation (r = 0.78), but only moderate agreement with a mean bias (LOA) of −0.37 (−1.69; +0.95) kPa showing an overestimation of the PaCO2. Sensitivity and specificity of PtcCO2 to detect changes of PaCO2 was 0.94 and 0.56, respectively. In no patient SpO2 or SaO2 values lower than 90 % were measured. Despite a moderate agreement between PaCO2 and PtcCO2 the PtcCO2 monitoring significantly reduced incidence, degree and duration of hypercapnia in shoulder surgery patients with MAC.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of combined oximetry and cutaneous capnography using a digital sensor with arterial blood gas analysisScandinavian Journal of Clinical and Laboratory Investigation, 2009
- Transcutaneous carbon dioxide profile during sleep reveals metabolic risk factors in post-menopausal femalesEuropean Respiratory Journal, 2009
- The effects of different analgesic regimens on transcutaneous CO 2 after major surgeryAnaesthesia, 2008
- An Evaluation of a New Combined Spo2/PtcCO2 Sensor in Very Low Birth Weight InfantsAnesthesia & Analgesia, 2008
- Accuracy and Precision of Three Different Methods to Determine Pco2 (Paco2 vs. Petco2 vs. Ptcco2) During Interhospital Ground Transport of Critically Ill and Ventilated AdultsJournal of Trauma: Injury, Infection & Critical Care, 2008
- Overnight variability in transcutaneous carbon dioxide predicts vascular impairment in womenExperimental Physiology, 2008
- Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy: Fig. 1—European Respiratory Journal, 2006
- The post-anesthesia recovery score revisitedJournal of Clinical Anesthesia, 1995
- Validity and Reliability of the Observer??sJournal of Clinical Psychopharmacology, 1990
- Cutaneous blood gas monitoring in the adultCritical Care Medicine, 1981