Clinical implementation of a multifaceted quality assurance phantom for high-precision radiation therapy: an institutional experience
Authors:
Open Access
- 1 September 2025
- journal article
- research article
- Published by Springer Nature in Journal of the Egyptian National Cancer Institute
- Vol. 37 (1) , 1-14
Abstract
Aim: This study aimed to evaluate the multifaceted clinical utility of the RUBY phantom as a comprehensive quality assurance (QA) platform in high-precision radiotherapy, particularly for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). The objective was to validate its performance in patient positioning, imaging system accuracy, isocenter congruency, and treatment plan verification across various complex clinical scenarios. Materials and methods: A series of QA workflows were conducted using the RUBY phantom and its dedicated modular inserts. These included CBCT and MV/kV planar imaging for patient alignment, the Winston-Lutz insert for isocenter verification, end-to-end testing for full-chain validation, and multi-metastasis and patient-specific inserts for point dose verification. Plans were created in Eclipse TPS (v15.6) and delivered using a Varian TrueBeam STx linear accelerator with high-definition MLC. PTW Semiflex 3D and PinPoint 3D ionization chambers were used for all dosimetric verifications. Results: CBCT- and planar image-guided alignments showed sub-millimetric deviations, with post-correction alignment verified through coincident laser and surface markers. Winston-Lutz testing across various angles demonstrated maximal deviations of ≤ 0.4 mm, which was within TG-142 recommendations. Point dose measurements for 61 SRS plans showed agreement within ± 3% of TPS calculations. End-to-end testing revealed dose discrepancies of < 1% in both coplanar and non-coplanar beam arrangements. Multi-target plans using single- and multi-isocenter approaches showed deviations of − 0.23% to − 0.50%, confirming excellent dosimetric and geometric accuracy. Conclusion: The RUBY phantom demonstrated exceptional precision, reproducibility, and clinical adaptability across a spectrum of advanced radiotherapy QA tasks. Its integration enables the end-to-end validation of modern treatment protocols, ensuring alignment, imaging, and accuracy of dose delivery. These findings establish the RUBY phantom as a cornerstone QA solution for enhancing safety, efficacy, and reliability in high-precision radiotherapy.Keywords
This publication has 33 references indexed in Scilit:
- Dose verification of 2 targets simultaneously for single-isocenter stereotactic radiation therapy and radiosurgery plansMedical Dosimetry, 2025
- Efficient quality assurance for isocentric stability in stereotactic body radiation therapy using machine learningRadiological Physics and Technology, 2023
- Evaluating the linear accelerator accuracy: Integrating Winston-Lutz measurement method and mathematical calculationsRadiation Physics and Chemistry, 2023
- End-to-end testing for stereotactic radiotherapy including the development of a Multi-Modality phantomZeitschrift für Medizinische Physik, 2022
- A simplified and effective off‐axis Winston–Lutz for single‐isocenter multi‐target SRSJournal of Applied Clinical Medical Physics, 2022
- Comparative study of SRS end‐to‐end QA processes of a diode array device and an anthropomorphic phantom loaded with GafChromic XD filmJournal of Applied Clinical Medical Physics, 2022
- Determination of commissioning criteria for multileaf‐collimator, stereotactic radiosurgery treatments on Varian TrueBeam and Edge machines using a novel anthropomorphic phantomJournal of Applied Clinical Medical Physics, 2022
- Comparison of three different phantoms used for Winston-Lutz test with Artiscan softwareReports of Practical Oncology and Radiotherapy, 2020
- Evaluation of the Impact of the Linac MLC and Gantry Sag in volumetric modulated arc therapyMedical Physics, 2019
- AAPM‐RSS Medical Physics Practice Guideline 9.a. for SRS‐SBRTJournal of Applied Clinical Medical Physics, 2017