Learning and non-learning algorithms for cuffless blood pressure measurement: a review
- 3 June 2021
- journal article
- review article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 59 (6) , 1201-1222
Abstract
The machine learning approach has gained a significant attention in the healthcare sector because of the prospect of developing new techniques for medical devices and handling the critical database of chronic diseases. The learning approach has potential to analyze complex medical data, disease diagnosis, and patient monitoring system, and to monitor e-health record. Non-invasive cuffless blood pressure (CLBP) measurement secured a significant position in the patient monitoring system. From a few recent decades, the importance of cuffless technology has been perceived towards continuous monitoring of blood pressure (BP) and supplementary efforts have been made towards its continuous monitoring. However, the optimal method that measures BP unambiguously and continuously has not yet emerged along with issues like calibration time, accuracy and long-term estimation of BP with miniaturizing hardware. The present study provides an insight into several learning algorithms along with their feature selection models. Various challenges and future improvements towards the current state of machine learning in healthcare industries are discussed in the present review. The bottom line of this study is to provide a comprehensive perspective of the machine learning approach of CLBP for the generation of highly precise predictive models for continuous BP measurement.Keywords
This publication has 105 references indexed in Scilit:
- Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technologyIntensive Care Medicine, 2013
- Beat-to-Beat Tracking of Systolic Blood Pressure Using Noninvasive Pulse Transit Time During Anesthesia Induction in Hypertensive PatientsAnesthesia & Analgesia, 2013
- Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressureJournal of Applied Physiology, 2011
- Continuous and Noninvasive Measurement of Systolic and Diastolic Blood Pressure by One Mathematical Model with the Same Model Parameters and Two Separate Pulse Wave VelocitiesAnnals of Biomedical Engineering, 2011
- Continuous Blood Pressure Monitoring in Daily LifeJournal of Advanced Mechanical Design, Systems, and Manufacturing, 2010
- Loose Cuff HypertensionCardiovascular Engineering, 2009
- Linear relationship between systolic and diastolic blood pressure monitored over 24 h: assessment and correlatesJournal Of Hypertension, 2008
- Model-based synthetic fuzzy logic controller for indirect blood pressure measurementIEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics), 2002
- Pulse Transit Time as an Indicator of Arterial Blood PressurePsychophysiology, 1981
- Measurements of Young's Modulus of Elasticity of the Canine Aorta with UltrasoundUltrasonic Imaging, 1979