Determination of Fracture Toughness JIc Under Quasi-Static and Dynamic Loading Conditions Using Wedge Loaded Specimens
Authors:
- 1 September 1984
- journal article
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 12 (5) , 316-323
Abstract
A study of the variation of fracture toughness of American Iron and Steel Institute (AISI) 1045 (Unified Numbering System [UNS] G10450) steel in the annealed condition, which exhibits elastic-plastic behavior at the crack tip, with loading rates ranging from quasi-static to dynamic conditions was undertaken. A wedge loaded compact tension (WLCT) specimen geometry was used in both testing conditions. The onset of crack propagation was detected using a strain gage mounted near the crack tip. The fracture parameter JIc decreases by about 50% when the loading rate ˙KI increases from 0.5 to about 106 MPa · m½ s−1. The measured values of JIc using WLCT specimens were confirmed from previous data on this material using standardized three-point bending specimens as well as from evaluation of JIc from stretch zone width measurements using scanning electron microscopy of the fracture surface of the WLCT specimens.Keywords
This publication has 15 references indexed in Scilit:
- Experimental correlation between ductility and J-integral in the transition region of 1045 steelEngineering Fracture Mechanics, 1983
- Determination of fracture toughness from stretch zone width measurement in predeformed AISI type 4340 steelMaterials Science and Engineering, 1982
- Discussion of a New Experimental Method in Measuring Fracture Toughness Initiation at High Loading Rates by Stress WavesJournal of Engineering Materials and Technology, 1982
- Fracture Toughness of 4130 Quenched and Tempered SteelJournal of Engineering Materials and Technology, 1981
- The Effect of Loading Rate and Temperature on the Initiation of Fracture in a Mild, Rate-Sensitive SteelJournal of Engineering Materials and Technology, 1979
- Fracture Initiation in Metals Under Stress Wave Loading Conditions1977
- Comparison of various methods of measuring kic on small precracked bend specimens that fracture after general yieldEngineering Fracture Mechanics, 1976
- A J Integral Analysis for the Compact Specimen, Considering Axial Force as Well as Bending EffectsJournal of Pressure Vessel Technology, 1974
- Dynamic Fracture Toughness Measurements of High-Strength Steels Using Precracked Charpy Specimens1974
- An Investigation of the Mechanical Properties of Materials at very High Rates of LoadingProceedings of the Physical Society. Section B, 1949