The response of phospholipid-encapsulated microbubbles to chirp-coded excitation: Implications for high-frequency nonlinear imaging
- 1 May 2013
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5) , 3145-3158
Abstract
The current excitation strategy for harmonic and subharmonic imaging (HI and SHI) uses short sine-bursts. However, alternate pulsing strategies may be useful for enhancing nonlinear emissions from ultrasound contrast agents. The goal of this study was to corroborate the hypothesis that chirp-coded excitation can improve the performance of high-frequency HI and SHI. A secondary goal was to understand the mechanisms that govern the response of ultrasound contrast agents to chirp-coded and sine-burst excitation schemes. Numerical simulations and acoustic measurements were conducted to evaluate the response of a commercial contrast agent (Targestar-P®) to chirp-coded and sine-burst excitation (10 MHz frequency, peak pressures 290 kPa). The results of the acoustic measurements revealed an improvement in signal-to-noise ratio by 4 to 14 dB, and a two- to threefold reduction in the subharmonic threshold with chirp-coded excitation. Simulations conducted with the Marmottant model suggest that an increase in expansion-dominated radial excursion of microbubbles was the mechanism responsible for the stronger nonlinear response. Additionally, chirp-coded excitation detected the nonlinear response for a wider range of agent concentrations than sine-bursts. Therefore, chirp-coded excitation could be a viable approach for enhancing the performance of HI and SHI.Keywords
This publication has 49 references indexed in Scilit:
- Improving the sensitivity of high‐frequency subharmonic imaging with coded excitation: A feasibility studyMedical Physics, 2012
- Excitation threshold for subharmonic generation from contrast microbubblesThe Journal of the Acoustical Society of America, 2011
- Dynamic manipulation of the subharmonic scattering of phospholipid-coated microbubblesPhysics in Medicine & Biology, 2011
- Characterization of Definity™ Ultrasound Contrast Agent at Frequency Range of 5–15 MHzUltrasound in Medicine & Biology, 2011
- Subharmonic behavior of phospholipid-coated ultrasound contrast agent microbubblesThe Journal of the Acoustical Society of America, 2010
- A dual-frequency excitation technique for enhancing the sub-harmonic emission from encapsulated microbubblesPhysics in Medicine & Biology, 2009
- Imaging of the vasa vasorumNature Clinical Practice Cardiovascular Medicine, 2008
- Contrast Harmonic Intravascular UltrasoundInvestigative Radiology, 2006
- Contrast Ultrasound Imaging of the Carotid Artery Vasa Vasorum and Atherosclerotic Plaque NeovascularizationJACC, 2006
- Oscillations of polymeric microbubbles: Effect of the encapsulating shellThe Journal of the Acoustical Society of America, 2000