Measurements of biomagnetic fields using a high-resolution dc superconducting quantum interference device magnetometer
Authors:
- 1 June 1998
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 83 (11) , 6465-6467
Abstract
We have developed a multichannel high-resolution superconducting quantum interference device magnetometer for measuring biomagnetic fields produced by small animals. We measured the magnetocardiogram produced by a rat. Topographies of the wave, wave, and wave of the rat magnetocardiogram were obtained. We also measured the magnetoretinogram, visually evoked magnetic fields, and auditory evoked magnetic fields of the rat. The signals of the magnetoretinogram appeared at 60 ms latency and the field intensities were about 0.6 pT. It was not possible to obtain the clear visually evoked fields because those signals were hidden behind the magnetoretinogram. It was possible to obtain auditory evoked magnetic fields of the rat. The significant differences of the wave forms were observed in both sides of the right ear, which are separated by 15 mm. Our system has adequate spatial resolution for measurement of the magnetocardiogram and auditory evoked magnetic fields produced by small animals.
Keywords
This publication has 1 reference indexed in Scilit: