Diagnostic Accuracy of 18F Choline PET/CT using Time-of-Flight Reconstruction Algorithm in Prostate Cancer Patients With Biochemical Recurrence
Authors:
- Daniel HausmannDHDaniel Hausmann
- Leonardo K. BittencourtLBLeonardo K. Bittencourt
- Ulrike I. AttenbergerUAUlrike I. Attenberger
- Anja WeidnerAnja Weidner
- Karen A. BüsingKBKaren A. Büsing
- Joachim BradeJBJoachim Brade
- Frederik WenzFWFrederik Wenz
- Stefan O. SchoenbergSSStefan O. Schoenberg
- Dietmar J. DinterDDDietmar J. Dinter
- 1 March 2014
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 39 (3) , e197-e201
Abstract
Image quality (IQ) of PET in voluminous body regions can be limited, which impairs the assessment of small metastatic lesions. Time-of-flight (TOF) reconstruction algorithm may deliver an increase of spatial resolution. The purpose of this study was to evaluate the impact of TOF on IQ, lesion detection rate, lesion volume (V) and SUVmax in F choline PET/CT of prostate cancer patients with biochemical recurrence compared to standard PET/CT reconstruction (standard). During a period of 9 months, 32 patients with prostate cancer (mean [SD] age, 71 [7.8] years) and biochemical recurrence were included in this prospective institutional review board-approved study. Each patient underwent a state-of-the-art 3-dimensional F choline PET/CT. A total of 76 lesions were assessed by 2 board-certified nuclear medicine physicians and a third-year resident. Lesion volume and SUVmax of local recurrence, lymph nodes, and organ metastases were compared between TOF and standard. Image quality and lesion demarcation were rated according to a 5-point Likert-type scale. Interobserver agreement was assessed. Eight additional lesions were detected using TOF (SUVmax, 3.64 [0.95]; V, 0.58 cm [0.50]). Image quality was reduced (IQ standard, 1.28; TOF, 1.77; P < 0.01) in calculated TOF images, although quality of lesion demarcation was improved (lesion demarcation: standard, 1.66; TOF, 1.26; P < 0.01). SUVmax was significantly increased in TOF images (SUVmax standard, 6.9 [4.1]; TOF, 8.1 [4.1]; P < 0.01), whereas V did not show significant differences (V standard, 5.3 [10.4] cm; TOF, 5.4 [10.3] cm; P = 0.41). Interobserver agreement was good for combined ratings (1 + 2 and 3 + 4). Application of TOF seems to be of additional value to detect small metastatic lesions in patients with prostate cancer and biochemical recurrence, which may have further clinical implications for secondary treatment.Keywords
This publication has 19 references indexed in Scilit:
- Prostate cancer epidemiology in the United StatesWorld Journal of Urology, 2012
- Impact of Time-of-Flight PET on Whole-Body Oncologic Studies: A Human Observer Lesion Detection and Localization StudyJournal of Nuclear Medicine, 2011
- An Assessment of the Impact of Incorporating Time-of-Flight Information into Clinical PET/CT ImagingJournal of Nuclear Medicine, 2010
- Impact of Time-of-Flight on PET Tumor DetectionJournal of Nuclear Medicine, 2009
- Benefit of Time-of-Flight in PET: Experimental and Clinical ResultsJournal of Nuclear Medicine, 2008
- The detection rate of [11C]Choline-PET/CT depends on the serum PSA-value in patients with biochemical recurrence of prostate cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Defining Biochemical Recurrence of Prostate Cancer After Radical Prostatectomy: A Proposal for a Standardized DefinitionJournal of Clinical Oncology, 2006
- First experimental results of time-of-flight reconstruction on an LSO PET scannerPhysics in Medicine & Biology, 2005
- The Effect of Finasteride on the Risk of Acute Urinary Retention and the Need for Surgical Treatment among Men with Benign Prostatic HyperplasiaNew England Journal of Medicine, 1998
- Photon Time-of-Flight-Assisted Positron Emission TomographyJournal of Computer Assisted Tomography, 1981