Felt Versus Pericardium for the Sandwich Technique in Type A Aortic Dissection: A Human Cadaver Study
Authors:
- Jasmine El-NasharJEJasmine El-Nashar
- Thomas PoschnerThomas Poschner
- Mohamed El DinMDMohamed El Din
- Paata PruidzePPPaata Pruidze
- Giorgi DidavaGDGiorgi Didava
- Amila KahrovicAKAmila Kahrovic
- Wolfgang J. WeningerWWWolfgang J. Weninger
- Daniel ZimpferDaniel Zimpfer
- Marek P. EhrlichMEMarek P. Ehrlich
- Emilio Osorio-JaramilloEOEmilio Osorio-Jaramillo
Open Access
- 31 October 2025
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (21) , 7736
Abstract
Background: The Sandwich technique is a commonly adopted method for reinforcing the dissected aortic wall during acute Type A aortic dissection (ATAAD) repair, using either felt or bovine pericardial strips. However, complications such as anastomotic bleeding, distal anastomotic new entry (DANE) and persistent false lumen (PFL) remain major challenges. This study evaluated and compared the sealing efficacy of felt versus pericardium in a human cadaver model. Methods: ATAAD was simulated in 20 fresh human cadavers. Repairs were performed using the sandwich technique with either felt (n = 10) or pericardium (n = 10), followed by end-to-end prosthetic graft anastomosis. Procedure time was recorded. Following the repair, the aortas were perfused at 160/90 mmHg using a glycerol-water solution to assess fluid leakage (mL), DANE and PFL. Results: Median leakage was significantly lower in the pericardium group (67.5 mL [IQR 40–198.8]) compared to the felt group (315 mL [IQR 285–445], p = 0.002). Procedure times were comparable between groups. DANE occurred in 20% (pericardium) and 30% (felt) of cases, while PFL was observed in 30% of cases in both groups; differences were not statistically significant. Conclusions: The superior sealing properties of pericardium in this study suggest a promising approach for reducing leakage in ATAAD repair. While rates of DANE and PFL were comparable, the advantage of pericardium was confined to leakage reduction. These findings highlight the need for further research to determine whether this experimental benefit translates into improved clinical outcomes.Keywords
This publication has 19 references indexed in Scilit:
- Distal anastomosis new entry tear in acute type A aortic dissection: A risk factor for distal aortic reoperationJTCVS Open, 2025
- Adventitial inversion plus prosthesis eversion suture technique in surgical repair of acute type A aortic dissectionJTCVS Techniques, 2023
- BioGlue cerebral embolism following acute type A aortic dissection repairJournal of Cardiology Cases, 2022
- Plaster technique for filling up a future entry at the suture hole in type A aortic dissectionIndian Journal of Thoracic and Cardiovascular Surgery, 2022
- Acute type A aortic dissection and the consequences of a patent false lumenJTCVS Techniques, 2021
- Type A Aortic Dissection Repair: How I Teach ItThe Annals of Thoracic Surgery, 2017
- Adventitial inversion technique without the aid of biologic glue or Teflon buttress for acute type A aortic dissectionEuropean Journal of Cardio-Thoracic Surgery, 2005
- Long-Term Integrity of Teflon Felt-Supported Suture Lines in Aortic SurgeryThe Annals of Thoracic Surgery, 2005
- Use of “BioGlue” in aortic surgical repairThe Annals of Thoracic Surgery, 2001
- Adventitial inversion technique in repair of aortic dissectionThe Annals of Thoracic Surgery, 1995