Use of separate venipunctures for IV access and laboratory studies decreases hemolysis rates
Authors:
- Shannon M. StraszewskiSSShannon M. Straszewski
- Leon SanchezLSLeon Sanchez
- Daniel McGillicuddyDMDaniel McGillicuddy
- Kirsten BoydKBKirsten Boyd
- Jane DuFresneJDJane DuFresne
- Nina JoyceNJNina Joyce
- Richard WolfeRWRichard Wolfe
- Alice W. LeeALAlice W. Lee
- Jonathan FisherJFJonathan Fisher
- John L. MottleyJMJohn L. Mottley
- 6 April 2011
- journal article
- research article
- Published by Springer Nature in Internal and Emergency Medicine
- Vol. 6 (4) , 357-359
Abstract
Emergency department (ED) patients routinely undergo placement of a saline lock device (SLD) with the aspiration of blood for laboratory testing. Drawing blood through a SLD may result in hemolysis of sample, repeated venipuncture and increased ED length of stay (LOS). The objective of this study was to examine if separate venipunctures for intravenous (IV) access and laboratory studies decrease the rate of hemolysis and ED LOS. The study was conducted at an urban university level 1 trauma center with an ED volume of 55,000. We compared the rate of hemolysis and ED LOS before and after mandating the use of separate venipunctures for IV access and laboratory studies over 1 month. Venipuncture was performed utilizing either a 21 ga needle or an IV catheter (BD Insight Autoguard) with a needless vacutainer. The incidence of hemolysis was calculated and a Student’s t test was used to compare groups. The potassium sample redraw and processing time was observed. Blood was aspirated from 315 patients using the SLD. A baseline hemolysis rate of 23.0% (16.7–29.1) was obtained, corrected to 6.7% after factoring a 29.2% redraw rate for critical potassium levels. In the following month, 2,564 samples were obtained using the butterfly needle with a hemolysis rate of 6.6% (5.5–7.5), corrected to 2.0% after applying the 29.2% redraw rate. Avoiding hemolysis, we saved 4.7% of our patients’ 56 min of ED stay, and avoided 185 retests over the month. In conclusion, venipuncture from a butterfly needle decreases the rate of hemolysis and may decrease the overall ED LOS.Keywords
This publication has 11 references indexed in Scilit:
- Observational Study to Determine Factors Associated with Blood Sample Haemolysis in the Emergency DepartmentAnnals of the Academy of Medicine, Singapore, 2008
- Nursing Blood Specimen Collection Techniques and Hemolysis Rates in an Emergency Department: Analysis of Venipuncture Versus Intravenous Catheter Collection TechniquesJournal of Emergency Nursing, 2008
- A quality improvement cycle: hemolyzed specimens in the emergency department.2008
- Comparison of Laboratory Values Obtained by Phlebotomy versus Saline Lock DevicesAcademic Emergency Medicine, 2007
- Comparison of Laboratory Values Obtained by Phlebotomy versus Saline Lock DevicesAcademic Emergency Medicine, 2007
- Thoughts on "The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples".2003
- Blood draws, hemolysis, needlestick prevention, and application of research findingsJournal of Emergency Nursing, 2003
- Accuracy of drawing blood through infusing intravenous linesHeart & Lung, 2001
- Reliability of an intravenous intermittent access port (saline lock) for obtaining blood samples for coagulation studiesAmerican Journal of Critical Care, 1999
- Intravenous catheter aspiration for obtaining basic analytes during intravenous infusionAnnals of Emergency Medicine, 1990