Experimental and Numerical Investigation of Steel‐Concrete Composite Shear Walls

Authors:

Abstract
Steel–concrete composite (SC) shear walls with double steel plates and concrete infill are a promising alternative to RC cores in high‐rise buildings. Within a composite‐core development programme, ArcelorMittal Global R&D, SCI and KIT have planned a full‐scale testing campaign on double‐skin composite (DSC) walls with steel boundary columns, a configuration not yet tested at full scale in Europe. Two nominally identical specimens are considered: one under monotonic lateral loading and one under a cyclic drift protocol, both with constant axial load. This paper reports the pre‐test phase: design of the wall modules, fabrication, test setup and loading protocols, and a nonlinear finite‐element analysis (FEA) of Specimen 1 under monotonic lateral loading. The walls are 3.14 m long, 1.0 m wide and 180 mm thick, with 5 mm S355 faceplates, IPE 180 S460 boundary columns and C40/50 self‐compacting concrete infill. The ABAQUS shell/solid model of Specimen 1 with concrete damage plasticity and tied/frictional steel–concrete interfaces predicts a flexural‐dominated response with plastic hinging near the base and local buckling of the compression faceplate. The forthcoming tests at KIT will be used in future work to benchmark and refine the numerical models and design assumptions.