Biometric measurements in highly myopic eyes
Authors:
- Yingfeng ZhengYZYingfeng Zheng
- Xiaohu DingXDXiaohu Ding
- Bin LiuBLBin Liu
- Nathan CongdonNCNathan Congdon
- Ian MorganIMIan Morgan
- Mingguang HeMHMingguang He
- 1 February 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (2) , 180-187
Abstract
To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Comparative evaluation of diagnostic technology. Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥ 27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. No author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 18 references indexed in Scilit:
- Desktop auxiliary apparatus for A-scan ultrasound: Repeatability and validityJournal of Cataract & Refractive Surgery, 2011
- Comparison and Evaluation of Ocular Biometry Using a New Noncontact Optical Low-Coherence ReflectometerOphthalmology, 2009
- Myopia genetics: a review of current research and emerging trendsCurrent Opinion in Ophthalmology, 2009
- Evaluation of the Lenstar LS 900 non-contact biometerBritish Journal of Ophthalmology, 2009
- Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial lengthJournal of Cataract & Refractive Surgery, 2008
- Biometry accuracy using zero- and negative-powered intraocular lensesJournal of Cataract & Refractive Surgery, 2005
- Intraocular lens power calculation formulas in Chinese eyes with high axial myopiaJournal of Cataract & Refractive Surgery, 2003
- Improved prediction of intraocular lens power using partial coherence interferometryJournal of Cataract & Refractive Surgery, 2001
- Intraocular lens power calculations in patients with extreme myopiaJournal of Cataract & Refractive Surgery, 2000
- DETERMINATION OF THE VELOCITY OF ULTRASOUND IN THE HUMAN LENS AND VITREOUSActa Ophthalmologica, 1962