Myoelectric or Force Control? A Comparative Study on a Soft Arm Exosuit
- 13 January 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 38 (3) , 1363-1379
Abstract
The intention-detection strategy used to drive an exosuit is fundamental to evaluate the effectiveness and acceptability of the device. Yet, current literature on wearable soft robotics lacks evidence on the comparative performance of different control approaches for online intention-detection. In the present work, we compare two different and complementary controllers on a wearable robotic suit, previously formulated and tested by our group; a model-based myoelectric control ( myoprocessor ), which estimates the joint torque from the activation of target muscles, and a force control that estimates human torques using an inverse dynamics model ( dynamic arm ). We test them on a cohort of healthy participants performing tasks replicating functional activities of daily living involving a wide range of dynamic movements. Our results suggest that both controllers are robust and effective in detecting human–motor interaction, and show comparable performance for augmenting muscular activity. In particular, the biceps brachii activity was reduced by up to 74% under the assistance of the dynamic arm and up to 47% under the myoprocessor , compared to a no-suit condition. However, the myoprocessor outperformed the dynamic arm in promptness and assistance during movements that involve high dynamics. The exosuit work normalized with respect to the overall work was $68.84 \pm 3.81\%$ when it was ran by the myoprocessor , compared to $45.29 \pm 7.71\%$ during the dynamic arm condition. The reliability and accuracy of motor intention detection strategies in wearable device is paramount for both the efficacy and acceptability of this technology. In this article, we offer a detailed analysis of the two most widely used control approaches, trying to highlight their intrinsic structural differences and to discuss their different and complementary performance.Keywords
Funding Information
- Carl-Zeiss-Stiftung
- National Center of Competence in Research Chemical Biology
This publication has 54 references indexed in Scilit:
- EMG-Driven Forward-Dynamic Estimation of Muscle Force and Joint Moment about Multiple Degrees of Freedom in the Human Lower ExtremityPLOS ONE, 2012
- Estimation of musculotendon kinematics in large musculoskeletal models using multidimensional B-splinesJournal of Biomechanics, 2012
- Having a body versus moving your body: Neural signatures of agency and body-ownershipNeuropsychologia, 2010
- Locomotor adaptation to a powered ankle-foot orthosis depends on control methodJournal of NeuroEngineering and Rehabilitation, 2007
- Learning to walk with a robotic ankle exoskeletonJournal of Biomechanics, 2007
- Virtual trajectory and stiffness ellipse during multijoint arm movement predicted by neural inverse modelsBiological Cybernetics, 1993
- Improving the efficacy of electrical stimulation-induced leg cycle ergometry: an analysis based on a dynamic musculoskeletal modelIEEE Transactions on Rehabilitation Engineering, 1993
- Optimum Settings for Automatic ControllersJournal of Dynamic Systems, Measurement, and Control, 1993
- Hill-Based Muscle Models: A Systems Engineering Perspective1990
- Electromechanical delay in human skeletal muscle under concentric and eccentric contractionsEuropean Journal of Applied Physiology, 1979