Two‐phase, steam‐water critical flow
Authors:
- 1 September 1957
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 3 (3) , 361-365
Abstract
Two‐phase critical flow of steam‐water mixtures has been investigated over a pressure range from 4 to 43 1b./sq.in. abs. and a quality range from saturated vapor to 1% (weight) vapor. Discharges were measured from 1/4‐,1/2‐, 3/4‐, and 1‐in. pipes and from annuli of intermediate cross‐sectional areas. The experimental mass flow rates are always grteater than the values calculated on the basis of a homogeneous flow model. Several empirical methods for correlating the data were determined, and comparisons are presented of the predictions of several analytical flow models.Keywords
This publication has 6 references indexed in Scilit:
- The Adiabatic Flow of Evaporating Fluids in Pipes of Uniform BoreProceedings of the Institution of Mechanical Engineers, Part B: Management and engineering manufacture, 1953
- Metastable Flow of Saturated WaterTransactions of the American Society of Mechanical Engineers, 1951
- Flow of a Flashing Mixture of Water and Steam Through Pipes and ValvesTransactions of the American Society of Mechanical Engineers, 1951
- Temperature and pressure phenomena in the flow of saturated liquidsProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1948
- Fluid Flow Through Two Orifices in Series—IITransactions of the American Society of Mechanical Engineers, 1944
- The Flow of a Flashing Mixture of Water and Steam Through PipesTransactions of the American Society of Mechanical Engineers, 1942