Microflow imaging: New Doppler technology to detect low-grade inflammation in patients with arthritis

Authors:

Abstract
Aim To assess the efficacy of microvascular imaging in detecting low-grade inflammation in arthritis compared with Power Doppler ultrasound (PDUS). Method and materials Patients presenting for ultrasound with arthralgia were assessed with grey-scale, PDUS and Superb Microvascular Imaging (SMI). Videoclips were stored for analysis at a later date. Three musculoskeletal radiologists scored grey-scale changes, signal on PDUS and/or SMI within these joints. If a signal was detected on both PDUS and SMI, the readers graded the conspicuity of vascular signal from the two Doppler techniques using a visual analogue scale. Results Eighty-three patients were recruited with 134 small joints assessed. Eighty-nine of these demonstrated vascular flow with both PD and SMI, whilst in five no flow was detected. In 40 joints, vascularity was detected with SMI but not with PDUS (p = 0.007). Out of the 89 joints with vascularity on both SMI and PDUS, 23 were rated as being equal; while SMI scored moderately or markedly better in 45 cases (p Key Points • SMI detects vascularity with improved resolution and sensitivity compared to Power Doppler. • SMI can detect low-grade inflammation not seen with Power Doppler. • Earlier detection of active inflammation could have significant impact on treatment paradigms.
Funding Information
  • Imperial College London

This publication has 17 references indexed in Scilit: