Magnetic localisation of a current dipole implanted in dogs
Authors:
- E Costa MonteiroEME Costa Monteiro
- A C BrunoABA C Bruno
- S R W LouroSLS R W Louro
- P Costa RibeiroPRP Costa Ribeiro
- A Fonseca CostaACA Fonseca Costa
- 1 January 1987
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 32 (1) , 65-70
Abstract
In order to evaluate the difficulty in localising a current dipole due to volume conductor current contributions to the magnetocardiogram, accuracy of depth localisation of a commercial coaxial pacemaker cable, used as a current dipole, was studied in two experimental situations: immersed in a prismatic container with NaCl solution and introduced into the lower oesophagus of dogs. Isofield contour maps were obtained by interpolation of the magnetic field measured over a plane and perpendicular to it with a third-order gradiometer coupled to a SQUID. The dipole can be accurately localised in the prismatic container. The observation of an isofield map that is symmetric about the maximum-minimum axis when the dogs are in the dorsal decubitus position with the dipole in the cephalocaudal direction implies that internal inhomogeneities in the dog's volume conductor produce no appreciable effect on the magnetic field. Nevertheless, a large distortion of the magnetic field lines is observed and can be explained by calculations using models that take into account the external boundary of the volume conductor.Keywords
This publication has 7 references indexed in Scilit:
- Magnetic localization of a dipolar current source implanted in a sphere and a human craniumElectroencephalography and Clinical Neurophysiology, 1986
- A symmetric third order gradiometer without external balancing or magnetocardiographyCryogenics, 1983
- On the influence of the volume conductor in magnetocardiography: an experimental approachIl Nuovo Cimento D, 1983
- The mapping of the measured cardiac electric potential and magnetic-field distributionIl Nuovo Cimento D, 1983
- Magnetic Fields of a Dipole in Special Volume Conductor ShapesIEEE Transactions on Biomedical Engineering, 1977
- Computer model studies of the magnetocardiogramAnnals of Biomedical Engineering, 1977
- Digital model for studies in magnetocardiographyIEEE Transactions on Magnetics, 1973