Evaluation of five portable blood glucose meters for use in dogs
Authors:
- Gerhard WessGWGerhard Wess
- Claudia ReuschCRClaudia Reusch
- 15 January 2000
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 216 (2) , 203-209
Abstract
Objective—To evaluate clinical and analytical accuracy of 5 portable blood glucose meters (PBGM) used to measure blood glucose concentrations in dogs and to determine potential sources of error. Design—Prospective study. Animals—221 dogs. Procedure—Venous blood samples were obtained, and results of the 5 PBGM were compared with results of a hexokinase reference method. Agreement among methods was determined by use of error grid analysis and statistical methods. Results—Accuracy of the PBGM varied with glucose concentration of the sample. The largest differences between results of the PBGM and results of the reference method were obtained with samples with high glucose concentrations; 4 PBGM tended to underestimate and 1 PBGM tended to overestimate the true glucose concentration. Absolute differences between results of the PBGM and results of the reference method were small for samples with low glucose concentrations and samples with concentrations in the reference range. None of the PBGM yielded measurements that would result in clinically unacceptable errors. Within-run and between-day precision was good for all PBGM, and results were not affected by use of EDTA or heparin to anticoagulate blood. Readings of the PBGM were significantly higher for blood samples with low Hct than for samples with normal Hct. For 3 PBGM, samples < 3 μl resulted in inaccurate measurements. Conclusions and Clinical Relevance—Results suggest that currently available PBGM are sufficiently accurate for use in clinical practice to determine blood glucose concentrations in dogs. ( J Am Vet Med Assoc 2000;216:203–209)Keywords
This publication has 21 references indexed in Scilit:
- Evaluation of a simplified intravenous glucose tolerance test and a reflectance glucose meter for use in catsVeterinary Record, 1997
- Influence of blood sample oxygen tension on blood glucose concentration measured using an enzyme-electrode methodCritical Care Medicine, 1997
- A comparison of statistical techniques to evaluate the performance of the glucometer elite® blood glucose meterClinical Biochemistry, 1996
- Accuracy of home blood glucose meters during hypoglycemiaDiabetes Care, 1996
- The Effect of Haemolysis on Blood Glucose Meter MeasurementDiabetic Medicine, 1995
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Performance of Seven Blood Glucose Testing Systems at High AltitudeThe Diabetes Educator, 1989
- What Do Statistics Really Tell Us About the Quality of the Data from Self-Monitoring of Blood Glucose?Diabetic Medicine, 1989
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986