Observer studies to assess new image processing devices or computer-aided diagnosis techniques are often performed, but little is known about the effect of the study design on observer performance results. We investigated the effect of the sequential and independent reading design on observer study results with respect to reader performance and their statistical power. For this we performed an observer study for the detection of lung nodules with bone-suppressed images (BSIs) compared with original chest radiographs. In a fully crossed observer study, eight observers assessed a series of 300 radiographs four times, including one assessment of the original radiograph with sequential BSI and two independent reading sessions with BSI. Observer performance was compared using multireader multicase receiver operating characteristics. No significant difference between the effect of BSI in the sequential and the independent reading sessions could be found (; ). Compared with the original radiographs, increased performance with BSI was significant in the sequential and one of the independent reading sessions (; ), and nonsignificant in the other independent reading session (). A strong increase of uncorrelated variance components was found in the independent reading sessions, masking the ability to demonstrate differences in observer performance across modalities. Therefore, the sequential reading design is the preferred design because it is less burdensome and has more statistical power.
Keywords
This publication has 22 references indexed in Scilit:
- What's the Control in Studies Measuring the Effect of Computer-Aided Detection (CAD) on Observer Performance?Academic Radiology, 2010
- Variability in Interpretive Performance at Screening Mammography and Radiologists’ Characteristics Associated with AccuracyRadiology, 2009
- A Framework for Random-Effects ROC Analysis: Biases with the Bootstrap and Other Variance EstimatorsCommunications in Statistics - Theory and Methods, 2009
- Recent Developments in the Dorfman-Berbaum-Metz Procedure for Multireader ROC Study AnalysisAcademic Radiology, 2008
- Improving mammographic decision accuracy by incorporating observer ratings with interpretation timeBritish Journal of Radiology, 2006
- Time-dependent observer errors in pulmonary nodule detectionBritish Journal of Radiology, 2006
- ACRIN—lessons learned in conducting multi-center trials of imaging and cancerCancer Imaging, 2005
- Variability in the Interpretation of MammogramsNew England Journal of Medicine, 1995
- Receiver Operating Characteristic Rating AnalysisInvestigative Radiology, 1992
- Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC StudiesInvestigative Radiology, 1989