Balloon-Expandable Transcatheter Aortic Valve Implantation for LVAD-Associated Native Aortic Insufficiency: A Single-Center Experience
Open Access
- 29 July 2026
- journal article
- research article
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (8) , 355
Abstract
Background: Aortic insufficiency (AI) during long-term left ventricular assist device (LVAD) support creates a maladaptive recirculatory loop that impairs forward flow, increases left ventricular filling pressures, leading to progressive congestion, and accelerates right ventricular dysfunction. Surgical correction carries high risk, making transcatheter aortic valve implantation (TAVI) an alternative strategy, although outcomes are challenged by complex annular geometry and the absence of calcific anchoring. Methods: We performed a retrospective single-center analysis of consecutive LVAD-supported patients undergoing TAVI for native AI. Annular sizing was area-based with a predefined oversizing strategy of approximately 15–30%, adjusted to annular geometry. Balloon-expandable valves were implanted using controlled deployment under rapid pacing and temporary LVAD flow reduction. Outcomes were assessed according to VARC-3 definitions. Results: Fourteen patients underwent TAVI. The cohort demonstrated high anatomical complexity, including annular eccentricity (median 0.21 [IQR 0.19–0.23]), horizontal aorta (42.9%), and flared left ventricular outflow tract (LVOT) morphology (50%). Median annular area was 528 mm2 (IQR 487–574), with area-derived diameter 25.9 mm (IQR 24.9–27.0). Mean oversizing was 21.9% (median 20.0%; range 15.1–30.3%). Technical and VARC-3 device success were achieved in 71.4%. Second valve implantation occurred in 28.6%. Procedural mortality was 0%. In-hospital mortality (21.4%) was related to low cardiac output and multi-organ dysfunction rather than device failure. No survivor had moderate or greater residual AI at discharge. Conclusions: In anatomically complex LVAD patients, an anatomy-driven balloon-expandable TAVI strategy achieved elimination of clinically significant AI with zero procedural mortality. In our interpretation, mortality reflected the advanced stage of heart failure at the time of intervention rather than acute device-related failure.Keywords
This publication has 24 references indexed in Scilit:
- Aortic insufficiency in the patient on contemporary durable left ventricular assist device support: A state-of-the-art review on preoperative and postoperative assessment and managementThe Journal of Heart and Lung Transplantation, 2024
- The Hemodynamic Effects of Aortic Regurgitation in Patients Supported by a HeartMate 3 Left Ventricular Assist DeviceJournal of Cardiac Failure, 2023
- Clinical Outcomes of Transcatheter Aortic Valve Replacement (TAVR) Vs. Surgical Aortic Valve Replacement (SAVR) in Patients With Durable Left Ventricular Assist Device (LVAD)Current Problems in Cardiology, 2022
- Aortic Insufficiency After Left Ventricular Assist Device Implantation: Predictors and OutcomesThe Annals of Thoracic Surgery, 2020
- Short-term results with transcatheter aortic valve replacement for treatment of left ventricular assist device patients with symptomatic aortic insufficiencyThe Journal of Heart and Lung Transplantation, 2019
- Aortic regurgitation in patients with a left ventricular assist device: A contemporary reviewThe Journal of Heart and Lung Transplantation, 2018
- Transcatheter Aortic Valve Replacement in Pure Native Aortic Valve RegurgitationJACC, 2017
- Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcomeThe Journal of Heart and Lung Transplantation, 2016
- Concomitant aortic valve procedures in patients undergoing implantation of continuous-flow left ventricular assist devices: An INTERMACS database analysisThe Journal of Heart and Lung Transplantation, 2015
- Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2010