Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen
- 26 September 2008
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (4) , 957-962
Abstract
Purpose: To evaluate motion correction effect and image quality in the upper abdomen with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique.Materials and Methods: A total of 50 consecutive patients underwent abdominal MR imaging. Fat‐saturated T2‐weighted turbo spin‐echo sequences were obtained by respiratory triggering. The subjects were examined with three different conditions of echo train length (ETL), blade width, and percent k‐space coverage in the same scanning time: 19/30/100%, 30/30/100%, and 30/52/175%, which were designated as L/C(1), L/C(2), and L/C(3), respectively. The parallel imaging acquisition technique was used to either reduce ETL from 30 to 19 in L/C(1) or increase k‐space coverage from 100% to 175% in L/C(3) compared with L/C(2). Motion and streak artifacts, and overall image quality were evaluated visually by two radiologists, independently.Results: Motion and streak artifacts were mostly reduced in L/C(3) condition. The L/C(3) image also gave the best overall image quality compared with other conditions (P < 0.001). The inter‐rater reliability for each evaluation agreed well.Conclusion: In upper abdominal BLADE MRI, it was possible to reduce image artifacts and obtain better image quality by increasing the k‐space coverage with parallel imaging in the same scanning time. J. Magn. Reson. Imaging 2008;28:957–962.Keywords
This publication has 23 references indexed in Scilit:
- Brain Magnetic Resonance Imaging at 3 Tesla Using BLADE Compared With Standard Rectilinear Data SamplingInvestigative Radiology, 2006
- Evaluation of Super Paramagnetic Iron Oxide-Enhanced Diffusion-Weighted PROPELLER T2-Fast Spin Echo Magnetic Resonance ImagingJournal of Computer Assisted Tomography, 2006
- Improved Image Quality and Detection of Acute Cerebral Infarction with PROPELLER Diffusion-weighted MR ImagingRadiology, 2002
- PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motionJournal of Magnetic Resonance Imaging, 2001
- Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imagingMagnetic Resonance in Medicine, 1999
- Reduction of motion artifacts in cine MRI using variable‐density spiral trajectoriesMagnetic Resonance in Medicine, 1997
- The diminishing variance algorithm for real‐time reduction of motion artifacts in MRIMagnetic Resonance in Medicine, 1995
- Projection Reconstruction Techniques for Reduction of Motion Effects in MRIMagnetic Resonance in Medicine, 1992
- Motion artifact suppression: A review of post-processing techniquesMagnetic Resonance Imaging, 1992
- Adaptive technique for high-definition MR imaging of moving structures.Radiology, 1989