CMM-Based Volumetric Assessment Methodology for Polyethylene Tibial Knee Inserts in Total Knee Replacement
Authors:
Open Access
- 10 April 2018
- journal article
- research article
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2018, 1-6
Abstract
Total knee replacement is a common surgical procedure in orthopaedics. Accurate volumetric wear assessment of the polyethylene knee inserts has been an essential subject for improving the longevity. A new CMM-based methodology was presented to determine volumetric material loss based on curve surface fitting without prewear data, CAD model, or original design of drawings. Both computational and experimental simulated volume removal tests were run to validate the methodology by comparing with the gravimetric measurements. The volume and linear wear of the tibial inserts were calculated using the presented method based on the coordinates acquired by the CMM. The results indicate that the methodology is adequate for clinically retrieved tibial inserts where no prewear data are provided. This technique can also be used for biotribological study of other polyethylene components, since wear and damage can be assessed visually and volumetrically.Keywords
Funding Information
- Scientific Research Foundation of Changzhou Institute of Technology (YN1626, YN1512, BK20150256)
- Scientific Research Foundation of Changzhou Institute of Technology (YN1626, YN1512, BK20150256)
- Applied Basic Research Programs of Science and Technology Commission Foundation of Jiangsu Province (YN1626, YN1512, BK20150256)
- NIHR LMBRU Leeds Musculoskeletal Biomedical Research Unit (YN1626, YN1512, BK20150256)
- Wellcome Trust (YN1626, YN1512, BK20150256)
- Centre of Excellence in Medical Engineering (YN1626, YN1512, BK20150256)
- Engineering and Physical Sciences Research Council (YN1626, YN1512, BK20150256)
This publication has 14 references indexed in Scilit:
- Polyethylene Wear in Knee ArthroplastyThe Journal of Knee Surgery, 2015
- The wear of fixed and mobile bearing unicompartmental knee replacementsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2011
- Three-Dimensional Surface Deviation Maps for Analysis of Retrieved Polyethylene Acetabular Liners Using Micro-Computed TomographyThe Journal of Arthroplasty, 2010
- CMM–based procedure for polyethylene non-congruous unicompartmental knee prosthesis wear assessmentWear, 2009
- Knee implants – Review of models and biomechanicsMaterials & Design (1980-2015), 2009
- Improvement in the assessment of wear of total knee replacements using coordinate-measuring machine techniquesProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2008
- Development of a technique for accurately determining clinical wear in explanted total hip replacementsWear, 2007
- Wear, Debris, and Biologic Activity of Cross-linked Polyethylene in the KneeClinical Orthopaedics and Related Research, 2004
- Polyethylene cross‐linking by two different methods reduces acetabular liner wear in a hip joint wear simulatorJournal of Orthopaedic Research, 2003
- Metrology to Quantify Wear and Creep of Polyethylene Tibial Knee InsertsClinical Orthopaedics and Related Research, 2003