Hospital‐based transfusion error tracking from 2005 to 2010: identifying the key errors threatening patient transfusion safety
Authors:
- 14 May 2013
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 54 (1) , 66-73
Abstract
Background: This report provides a comprehensive analysis of transfusion errors occurring at a large teaching hospital and aims to determine key errors that are threatening transfusion safety, despite implementation of safety measures.Study Design and Methods: Errors were prospectively identified from 2005 to 2010. Error data were coded on a secure online database called the Transfusion Error Surveillance System. Errors were defined as any deviation from established standard operating procedures. Errors were identified by clinical and laboratory staff. Denominator data for volume of activity were used to calculate rates.Results: A total of 15,134 errors were reported with a median number of 215 errors per month (range, 85‐334). Overall, 9083 (60%) errors occurred on the transfusion service and 6051 (40%) on the clinical services. In total, 23 errors resulted in patient harm: 21 of these errors occurred on the clinical services and two in the transfusion service. Of the 23 harm events, 21 involved inappropriate use of blood. Errors with no harm were 657 times more common than events that caused harm. The most common high‐severity clinical errors were sample labeling (37.5%) and inappropriate ordering of blood (28.8%). The most common high‐severity error in the transfusion service was sample accepted despite not meeting acceptance criteria (18.3%). The cost of product and component loss due to errors was $593,337.Conclusion: Errors occurred at every point in the transfusion process, with the greatest potential risk of patient harm resulting from inappropriate ordering of blood products and errors in sample labeling.Keywords
This publication has 21 references indexed in Scilit:
- Trimming the fat with an IVIG approval processTransfusion and Apheresis Science, 2012
- Transfusion‐associated circulatory overload after plasma transfusionTransfusion, 2011
- Transfusion practice and safety: current status and possibilities for improvementVox Sanguinis, 2010
- ‘Wrong blood in tube’: solutions for a persistent problemVox Sanguinis, 2010
- Incidence and transfusion risk factors for transfusion‐associated circulatory overload among medical intensive care unit patientsTransfusion, 2010
- Frequency and Outcomes of Blood Products Transfusion Across Procedures and Clinical Conditions Warranting Inpatient Care: An Analysis of the 2004 Healthcare Cost and Utilization Project Nationwide Inpatient Sample DatabaseAmerican Journal of Medical Quality, 2010
- Staff attitudes about event reporting and patient safety culture in hospital transfusion servicesTransfusion, 2008
- Nearly Two Decades Using the Check-Type to Prevent ABO-Incompatible TransfusionsAmerican Journal of Clinical Pathology, 2006
- Current performance of patient sample collection in the UKTransfusion Medicine, 2004
- Bedside Transfusion ErrorsVox Sanguinis, 1994