Comparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffé reaction
Authors:
- 1 January 1994
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 8 (6) , 391-399
Abstract
This study compared the effect of sodium dodecyl‐sulfate, potassium ferricyanide, and preincubation technique to continuous‐flow analysis and prior deproteinization to correct the negative interference of bilirubin on serum creatinine found by the kinetic Jaffé reaction. Bilirubin increased to 684 μmol/L did not interfere with serum creatinine measured by the methods incorporated with dialysis or deproteinization. Trichloroacetic acid was the best protein precipitant. The reagent incorporated with sodium dodecyl sulfate was more appropriate to minimize bilirubin interference than reagent containing potassium ferricyanide. An increase in potassium ferricyanide concentration resulted in false positive creatinine values. Incorporation of both SDS and potassium ferricyanide in the reagent did not help in minimizing the bilirubin interference over use of each chemical alone. The 10 minutes of preincubation of the sample with alkaline buffer incorporating with either SDS or potassium ferricyanide before starting the Jaffé reaction was the appropriate way to overcome unconjugated bilirubin interference at a level of 342.0 μmol/L. However, the technique did not work uniformly with icteric patient sera containing conjugated, unconjugated, and delta bilirubin. This is a challenging problem that remains to be solved by the clinical chemist.Keywords
This publication has 21 references indexed in Scilit:
- Negative Interference in a Kinetic Jaffé Method for Serum Creatinine DeterminationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1988
- Development of an automated kinetic Jaffé method designed to minimise bilirubin interference in plasma creatinine assaysClinica Chimica Acta, 1987
- Investigations into Negative Interference by Jaundiced Plasma in Kinetic Jaffé Methods for Plasma Creatinine DeterminationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1987
- Bilirubin analysis—The state of the art and future prospectsClinical Biochemistry, 1984
- Evaluation of serum creatinine measurement by the direct acidification method for errors contributed by non-creatinine chromogensClinica Chimica Acta, 1980
- The effect of bilirubin and ketones on reaction rate methods for the measurement of creatinineClinical Biochemistry, 1978
- Interesting interferences in a direct serum creatinine reactionMicrochemical Journal, 1976
- Determination of serum creatinine by a direct colorimetric methodClinica Chimica Acta, 1973
- A Kinetic Method for Analysis of Creatinine Using the DSA-560Analytical Letters, 1972
- Creatinine assay in the presence of proteinClinica Chimica Acta, 1971