Detection of Left Ventricular Thrombus by Cardiac Magnetic Resonance in Embolic Stroke of Undetermined Source

Authors:

Abstract
Background and Purpose—: We aimed to use contrast-enhanced cardiac magnetic resonance (CE-CMR) imaging to elucidate the prevalence of left ventricular (LV) thrombus in patients suspected of embolic stroke of undetermined source (ESUS) with previous myocardial infarction or LV dysfunction (LV ejection fraction [LVEF] P =0.04). Importantly, 29% (4 of 14) of patients with ESUS had LV thrombus. A prediction model based on CE-CMR findings showed higher performance in LV thrombus detection, permitting a net improvement of 0.46 (95% confidence interval, 0.08–0.82; P =0.016) in cardioembolic stroke reclassification. Compared with patients without LV thrombus, those with LV thrombus had lower LVEF (median: 26% versus 40%; P =0.003). Notably, 42% (5 of 12) of patients with LV thrombus had LVEF≥30%. Conclusions—: When ESUS-suspected patients have myocardial infarction or LV dysfunction, CE-CMR may help improve detection of cardioembolic stroke and provide relevant information for anticoagulation therapy. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT02251665.

This publication has 27 references indexed in Scilit: