Arthroscopic centralization reduces extrusion of the medial meniscus with posterior root defect in the ACL reconstructed knee
- 16 September 2022
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (2) , 543-550
Abstract
Purpose: The purpose of this study was to evaluate the effects of arthroscopic meniscal centralization reinforcement for a medial meniscus (MM) posterior root defect on knee kinematics and meniscal extrusion in the anterior cruciate ligament reconstructed (ACLR) knee.The hypothesis was that the medial meniscus centralization would reduce extrusion and anterior laxity in ACLR knee with a medical meniscal defect.Methods: Fourteen fresh‐frozen human cadaveric knees were tested using a six‐degrees‐of‐freedom robotic system under the following loading conditions: (a) an 89.0 N anterior tibial load, (b) 5.0 Nm internal and external rotational torques, (c) a 10.0 Nm valgus and varus loadings, and (d) a combined 7.0 Nm valgus moment and then a 5.0 Nm internal rotation torque as a static simulated pivot shift. The tested knee states included: (1) anatomic single‐bundle cruciate ligament reconstruction with intact medial meniscus (MM Intact), (2) anatomic single‐bundle cruciate ligament reconstruction with medial meniscus posterior root defect (MM Defect), (3) Anatomic single‐bundle cruciate ligament reconstruction with medial meniscus arthroscopic centralization (MM Centralization). Medial meniscus arthroscopic centralization was performed using 1.4 mm anchors with #2 suture. The MM extrusion (MME) was measured using ultrasound under unloaded and varus loading conditions at 0° and 30° of flexion.Results: Anterior tibial translation (ATT) increased significantly with MM posterior root defect compared to MM intact at all flexion angles. With MM centralization, ATT was not significantly different from the intact meniscus at 15° and 30° of flexion. Meniscus extrusion increased significantly with the root defect compared to intact meniscus and decreased significantly with meniscal centralization compared to the root defect at both flexion angles.Conclusions: In ACL reconstruction, cases involving irreparable medial meniscal posterior root tears, applying arthroscopic centralization for avoiding the meniscal extrusion should be considered. Clinically, in ACL reconstruction cases with irreparable medial meniscal posterior root tears, applying arthroscopic meniscal centralization for avoiding the meniscal extrusion should be considered. Meniscal centralization decreases the extrusion of the MM and offers improvements in knee laxity.Keywords
This publication has 21 references indexed in Scilit:
- ACL Graft Position Affects in Situ Graft Force Following ACL ReconstructionJournal of Bone and Joint Surgery, 2015
- Test–Retest Reliability of Single Transverse versus Panoramic Ultrasound Imaging for Muscle Size and Echo Intensity of the Biceps BrachiiUltrasound in Medicine & Biology, 2015
- Arthroscopic Centralization of an Extruded Lateral MeniscusArthroscopy Techniques, 2012
- Comparison of In Situ Forces and Knee Kinematics in Anteromedial and High Anteromedial Bundle Augmentation for Partially Ruptured Anterior Cruciate LigamentThe American Journal of Sports Medicine, 2010
- Biomechanical Comparisons of Knee Stability After Anterior Cruciate Ligament Reconstruction Between 2 Clinically Available Transtibial ProceduresThe American Journal of Sports Medicine, 2010
- Biomechanical Consequences of a Tear of the Posterior Root of the Medial MeniscusJournal of Bone and Joint Surgery, 2008
- G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciencesBehavior Research Methods, 2007
- Lateral Meniscus Root Tear and Meniscus Extrusion with Anterior Cruciate Ligament TearRadiology, 2006
- The effect of axial tibial torque on the function of the anterior cruciate ligamentArthroscopy, 2002
- Meniscal subluxation: association with osteoarthritis and joint space narrowingOsteoarthritis and Cartilage, 1999