Diagnostic Performance of Photon‐Counting Coronary CT Angiography in Patients Undergoing TAVI: A Comparison With Invasive Angiography
Open Access
- 25 November 2026
- journal article
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 56 (12)
Abstract
Background: Since coronary artery disease (CAD) is common in patients undergoing transcatheter aortic valve implantation (TAVI), invasive coronary angiography (ICA) is performed in preparation for the procedure, although many patients do not require coronary intervention. Photon‐counting Computed Tomography (PCCT) offers improved spatial resolution compared with conventional energy‐integrating detector CT. The aim of this study was to evaluate the diagnostic performance of PCCT for the detection of significant CAD in patients undergoing TAVI evaluation using ICA as the reference standard. Methods: In this single‐center study, 201 consecutive patients undergoing preprocedural TAVI work‐up with both PCCT and ICA were included. Sensitivity, specificity, and positive and negative predictive values (PPV and NPV) were calculated at ≥ 50% and ≥ 70% stenosis thresholds using recorded binary classifications. Non‐evaluable coronary territories were considered CT‐positive. Patient‐level 95% confidence intervals (CIs) were exact binomial; vessel‐level CIs used patient‐cluster bootstrap resampling. Results: Of 201 patients were included (mean age 79.6 ± 7.2 years; 118 [58.7%] male). Image quality was excellent or good in 167 patients (83.1%). On ICA, ≥ 50% stenoses were present in 126 patients (62.7%) and ≥ 70% stenoses in 114 (56.7%). For ≥ 50% stenosis, per‐patient sensitivity, specificity, PPV, and NPV were 98.4% (95% CI, 94.4%–99.8%), 93.3% (85.1%–97.8%), 96.1% (91.2%–98.7%), and 97.2% (90.3%–99.7%), respectively. Corresponding values for ≥ 70% stenosis were 99.1% (95.2%–100.0%), 89.7% (81.3%–95.2%), 92.6% (86.5%–96.6%), and 98.7% (93.1%–100.0%). At the ≥ 50% threshold, 72 patients (35.8%) were CT‐negative; 70 were true negatives and two were false negatives. Conclusions: PCCT demonstrates high diagnostic accuracy for the detection and exclusion of significant CAD in patients undergoing TAVI evaluation. PCCT coronary angiography may serve as a non‐invasive gatekeeper to invasive coronary angiography and support a more efficient pre‐procedural workflow.This publication has 16 references indexed in Scilit:
- Timing of PCI in Patients Undergoing Transcatheter Aortic-Valve ImplantationThe New England journal of medicine, 2026
- Accuracy of Photon-counting Detector CT Angiography for the Diagnosis of Obstructive Coronary Artery Disease: A Bayesian Diagnostic Test Accuracy Meta-AnalysisRadiology: Cardiothoracic Imaging, 2025
- 2025 ESC/EACTS Guidelines for the management of valvular heart diseaseEuropean Heart Journal, 2025
- Photon-counting CT: An updated review of clinical resultsEuropean Journal of Radiology, 2025
- PCI in Patients Undergoing Transcatheter Aortic-Valve ImplantationThe New England journal of medicine, 2024
- Photon-Counting Versus Dual-Source CT for Transcatheter Aortic Valve Implantation PlanningAcademic Radiology, 2024
- ACTIVATION (PercutAneous Coronary inTervention prIor to transcatheter aortic VAlve implantaTION)JACC: Cardiovascular Interventions, 2021
- 2021 ESC/EACTS Guidelines for the management of valvular heart diseaseEuropean Heart Journal, 2021
- Review of Technical Advancements and Clinical Applications of Photon-counting Computed Tomography in Imaging of the ThoraxJournal of Thoracic Imaging, 2021
- Atrial Fibrillation: Diagnostic Accuracy of Coronary CT Angiography Performed with a Whole-Heart 230-µm Spatial Resolution CT ScannerRadiology, 2017