Abstract
A study has been made of the analytical application of a nafcillin-imprinted sol−gel to the direct determination of the β-lactamic antibiotic in spiked milk-based samples using a room temperature phosphorescent flow-through system. The influence of the sample matrix on the transduction and the recognition processes was statistically determined, and results demonstrated that the imprinted sol−gel optosensing system could be effectively applied to real sample analysis. The analytical performance characteristics were as follows: The detection limit results for aqueous and skimmed milk were 5.8 × 10-6 and 3.3 × 10-5 mol L-1, respectively, and a relative standard deviation less than 5% was found for both matrices. Statistical analysis of variance studies have been shown to have no significant effect on different skimmed milk commercial products over the imprinted material recognition. This fact provides an indicator of the ruggedness/robustness of the proposed analytical system and the possibility to use external real matrix calibration. Application of the method to nafcillin analysis in other milk-based samples is outlined. Keywords: Molecular imprinting polymers; sol−gel materials; room-temperature phosphorescence; milk-based products; nafcillinKeywords
This publication has 7 references indexed in Scilit:
- Molecular imprinted ormosils for nafcillin recognition by room temperature phosphorescence optosensingBiosensors and Bioelectronics, 2006
- Molecularly imprinted polymers—potential and challenges in analytical chemistryAnalytica Chimica Acta, 2005
- Characterization of the heterogeneous binding site affinity distributions in molecularly imprinted polymersJournal of Chromatography B, 2004
- Sensitive flow-injection system for nafcillin determination based on non-protected room temperature phosphorescenceAnalytica Chimica Acta, 2003
- Food Analyses Using Molecularly Imprinted PolymersJournal of Agricultural and Food Chemistry, 2001
- Guidelines for calibration in analytical chemistry. Part I. Fundamentals and single component calibration (IUPAC Recommendations 1998)Pure and Applied Chemistry, 1998
- Nomenclature in evaluation of analytical methods including detection and quantification capabilities (IUPAC Recommendations 1995)Pure and Applied Chemistry, 1995