Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)
Authors:
- on behalf of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)O(on behalf of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM)
- Roberto SciagràRSRoberto Sciagrà
- Alessia GimelliAGAlessia Gimelli
- Fabien HyafilFHFabien Hyafil
- 5 February 2016
- journal article
- review article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 43 (8) , 1530-1545
Abstract
Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice.Keywords
This publication has 152 references indexed in Scilit:
- Resolution modeling in PET imaging: Theory, practice, benefits, and pitfallsMedical Physics, 2013
- Effects of Radiation Exposure From Cardiac ImagingJACC, 2012
- Improved Cardiac Risk Assessment With Noninvasive Measures of Coronary Flow ReserveCirculation, 2011
- Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomographyJournal of Nuclear Cardiology, 2011
- Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PETJournal of Nuclear Medicine, 2009
- Repeatability of regional myocardial blood flow calculation in 82Rb PET imagingBMC Medical Physics, 2009
- Quantitative relationship between coronary vasodilator reserve assessed by 82Rb PET imaging and coronary artery stenosis severityEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Effect of Reconstruction Algorithms on Myocardial Blood Flow Measurement with 13N-Ammonia PETJournal of Nuclear Medicine, 2007
- Quantification of myocardial blood flow with 82Rb dynamic PET imagingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2007
- Effects of long-term treatment with carvedilol on myocardial blood flow in idiopathic dilated cardiomyopathyHeart, 2007