Application of the 2015 proposed NIOSH vapor containment performance protocol for closed system transfer devices used during pharmacy compounding and administration of hazardous drugs
Authors:
- 24 July 2018
- journal article
- research article
- Published by SAGE Publications in Journal of Oncology Pharmacy Practice
- Vol. 25 (5) , 1160-1166
Abstract
Purpose: The National Institute for Occupational Safety and Health (NIOSH) released a proposed protocol in 2015 to evaluate the vapor containment abilities of closed system transfer device technologies in order to provide meaningful comparisons between products. This study assessed the vapor containment ability of closed system transfer devices when following the methodology as outlined by the 2015 NIOSH proposed protocol. Methods: This study evaluated six closed system transfer device brands following the draft NIOSH vapor containment protocol. The testing evaluated each closed system transfer device brand during both compounding (Task 1) and administration (Task 2). Five pre-specified steps for each task were repeated for a total of four manipulations per device. The Thermo Scientific™ MIRAN SapphIRe XL Infrared Analyzer was used to detect isopropyl alcohol vapor levels after each step. Results: For Task 1, two closed system transfer device products (PhaSeal™ and Equashield®) adequately contained the isopropyl alcohol vapor and passed the predefined testing criteria. The same two products, plus one additional product (ChemoLock™), contained the vapor for Task 2 manipulations. Based on the results of this study, only two out of the six closed system transfer device brands passed testing criteria for both tasks, functioning as truly closed systems. Conclusion: To improve employee safety in chemotherapy preparation, closed system transfer devices that demonstrate no leakage should be the preferred choices of healthcare systems. In this study, PhaSeal™ and Equashield® proved to be adequately closed in both Task 1 and Task 2, while ChemoLock™ proved to be closed in Task 2 but not in Task 1. All other products failed both tasks when measuring for isopropyl alcohol vapor release.Keywords
Funding Information
- Equashield, LLC
This publication has 18 references indexed in Scilit:
- Syringe plunger contamination by hazardous drugs: A comparative studyJournal of Oncology Pharmacy Practice, 2014
- Leakage from closed-system transfer devices as detected by a radioactive tracerAmerican Journal of Health-System Pharmacy, 2013
- Reduction in Surface Contamination with Cyclophosphamide in 30 US Hospital Pharmacies following Implementation of a Closed-System Drug Transfer DeviceHospital Pharmacy, 2013
- ASHP national survey of pharmacy practice in hospital settings: Dispensing and administration—2011American Journal of Health-System Pharmacy, 2012
- Chromosome 5 and 7 Abnormalities in Oncology Personnel Handling Anticancer DrugsJournal of Occupational and Environmental Medicine, 2010
- Reduction in surface contamination with antineoplastic drugs in 22 hospital pharmacies in the US following implementation of a closed-system drug transfer deviceJournal of Oncology Pharmacy Practice, 2010
- Nurses With Dermal Exposure to Antineoplastic DrugsEpidemiology, 2007
- Comparison of surface contamination with cyclophosphamide and fluorouracil using a closed-system drug transfer device versus standard preparation techniquesAmerican Journal of Health-System Pharmacy, 2006
- Bladder Cancer in a 39 Year-Old Female PharmacistJNCI: Journal of the National Cancer Institute, 1993
- MUTAGENICITY IN URINE OF NURSES HANDLING CYTOSTATIC DRUGSThe Lancet, 1979