Abstract
This article studies the permanent magnet demagnetization fault in permanent magnet synchronous machines (PMSM). The study is carried out by analyzing the harmonics obtained using the fast Fourier transform (FFT) of stator and zero sequence currents at nominal torque for the whole range of machine operation speeds. The appropriate combination of analyses on the different currents makes it possible to determine the faults for any speed range